Methods Inf Med 1968; 07(04): 209-214
DOI: 10.1055/s-0038-1636221
Original Article
Schattauer GmbH

A Multi-Terminal Cathode Ray Tube System for Man-Computer-Interfacing [*)]

EIN MEHRFACH-ANSCHLUSS-KATHODENSTRAHLRÖHREN-SYSTEM ZUM DIALOG ZWISCHEN MENSCH UND MASCHINE
P. L. Reichertz
,
A. W. Templeton
,
L. J. DeLurgio
Further Information

Publication History

Publication Date:
19 February 2018 (online)

A FORTRAN compatible, Physician-Computer-Interfacing System (FCMTS) has been developed utilizing up to 24 cathode-ray tube terminals with one set of programs. The system is designed for IBM 360 computers (Model 40 and upwards) under OS and IBM 2260 terminals. It is written for local operation and interrupt control. Time consuming polling is not necessary.

According to the intended application, a FORTRAN program set has to be supplied. It must consist of a sub-executive and application oriented task routines. The sub-executive controls the logic followed by the individual terminals. The task routines perform the different tasks of the application. FCMTS has been developed for ‘RADIATE’, a system for the synthesis, formatting and transmission of radiology reports. In its current version, up to 8 CRTs may be used at the same time. FCMTS may be utilized for diagnostic routines, for compilation of patient histories and data of physical examinations, and for any other dialogue between physician and computer.

Um den Dialog zwischen Arzt und Computer zu ermöglichen, wurde ein FORTRAN-kompatibles System (FCMTS) entwickelt. Es gestattet, von bis zu 24 Kathodenstrahlröhren aus gleichzeitig mit demselben Programm zu arbeiten. FCMTS wurde für IBM 360-Computer (Modell 40 und aufwärts) und IBM 2260 Kathodenstrahlröhren unter Benutzung von OS geschrieben. Es wird in lokalem Operationsmodus von den einzelnen Benutzerstationen direkt gesteuert; eine zeitraubende Abfrage erfolgt nicht. Zu seiner Anwendung ist die Erstellung eines FORTRAN-Programmsatzes notwendig, der aus einem Kontrollprogramm und mehreren Unterprogrammen (Funktionsprogrammen) besteht, die Aufgaben der speziellen Anwendungen durchführen. Das Kontrollprogramm steuert den Programmablauf für die einzelnen Benutzerstationen. Die Funktionsprogramme werden von dem Kontrollprogramm entsprechend dem Anwendungsablauf bei den einzelnen Benutzerstationen aktiviert.

FCMTS wurde für RADIATE entwickelt, ein System zur Erstellung, Schematisierung und Übermittlung von Röntgenberichten. In dieser Anwendung können derzeit 8 Kathodenstrahlröhren gleichzeitig benutzt werden. FCMTS ist anwendbar für diagnostische Programme, für die Erstellung von Anamnesen und Untersuchungsberichten sowie für jeden anderen Dialog zwischen Arzt und Computer.

*) (This investigation has been supported by Grant US PH RM 00009-01-0 MSR).


 
  • References

  • 1 Brown D. W. The Use of the Digital Computer in Organ Scanning. Conf. Use Computers in Radiology; Chicago: 1966
  • 2 Lodwick G. S. Radiographic Diagnosis and Grading of Bone Tumors with Comments on Computer Evaluation. Proc. 5th Nat. Cancer Conf; Philadelphia: September 1964: 369-380 (J. B. Lippincott, Philadelphia 1965)
  • 3 Lodwick G. S, Turner A. H, Lusted L. B, Templeton A. W. Computer-Aided Analysis of Radiographic Images. J. chron. Dis 19: 485-496 1966;
  • 4 Lodwick G. S. A Probabilistic Approach to Diagnosis of Bone Tumors. Rad. Clinics of North America Vol 111 (03) 487-497 1965;
  • 5 Lodwick G. S. Solitary Malignant Tumors of Bone. The Application of Predictor-Variables in Diagnosis. Sem. Roentgenol 1: 293-313 1966;
  • 6 Lodwick G. S. The Development of a Public Model. Nat. Conf. Computer Appl. Radiol; Columbia/Mo: 1967
  • 7 Reichertz P. L. Computer-Diagnostik von Extremitäten-Elektrokardiogrammen mittels formaler und parametrischer Vergleiche. Arch. Kreislaufforsch 53: 161-173 1967;
  • 8 Reichertz P. L, Overall J. E. Orthogonalisierung und vektorkardiographische Auswertung von Extremitäten-Elektrokardiogrammen mittels statistischer Methoden. 8.. Colloquium vectorcardiographicum. Wien: 1967
  • 9 Reichertz P. L. PCI (Physician-Computer-Interfacing). Example of Radiate and Diagnosis of Primary Bone Tumor.. Bioeng. Conf. Comp. Med.; Columbia/Mo: October 1967
  • 10 Templeton A. W, Lodwick G. S, Tuhner A. H. Radiate — A New Concept for Computer Coding, Transmitting, Storing and Retrieving Radiological Data. Radiology 35: 811-817 1965;
  • 11 Templeton A. W. Radiate — A Radiological (and Hospital) Computer-Oriented Communicating System.. Conf. Use Comp. Radiol.; Chicago: 1966
  • 12 Templeton A. W, Sides S. D. Radiate — A Radiology (and Hospital) Computer Oriented Communicating System.. Nat. Conf. Comp. Appl. Radiol.; Columbia/Mo.: April 1967
  • 13 Templeton A. W. Computer Aided Diagnosis in Pulmonary Nodules and Heart Disease.. Nat. Conf. Comp. Appl. Radiol.; Columbia/Mo.: April 1967
  • 14 Templeton A. W, Lehh J. L, Simmons C. The Computer Evaluation and Diagnosis of Congenital Heart Disease, Using Roentgenographs Findings. Radiology 87: 658-682 1966;
  • 15 Templeton A. W, Lodwick G. S, Sides S. D, Lehb J. L. Radiate — A Project for the Synthesis, Storage and Retrieval of Radiologic Consultations. 7th Internat Conf. Med. Biol. Engin; Stockholm/Sweden: August 1967
  • 16 Templeton A. W, Reichehtz P. L, Paquet E, Lodwick G. S, Lehh J. L, Scott F. L. »Radiate«, Up-Dated and Re-Designed for Multiple Terminals.. (Submitted for Publication).
  • 17 Wahner H. R, Toronto A. F, Veast G. L. Experience with Bayes’ Theorem for Computer Diagnosis of Congenital Heart Disease. Ann. N.Y. Acad. Sei 115: 558-567 1964;
  • 18 Wilson W. J, Templeton A. W, Turner A. H, Lodwick G. S. The Computer Analysis of Gastric Ulcers. Radiology 85: 1064-1073 1965;
  • 19 Winkleh C. Szintigrafischer Nachweis minimaler Aktivitätsdifferenzen in parenchymatösen Organen.. Fortschr. Röntgenstr., Sonderbd. Dtsch. Röntgenkongr; 1964: 55 Tgg., S. 59; Thieme, Stuttgart: 1965