J Wrist Surg 2015; 04(04): 292-300
DOI: 10.1055/s-0035-1565926
Scientific Article
Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Volar, Intramedullary, and Percutaneous Fixation of Distal Radius Fractures

Ram Alluri
1   Department of Orthopaedic Surgery, Keck Medical Center of University of Southern California, Los Angeles, California
,
Matthew Longacre
1   Department of Orthopaedic Surgery, Keck Medical Center of University of Southern California, Los Angeles, California
,
William Pannell
1   Department of Orthopaedic Surgery, Keck Medical Center of University of Southern California, Los Angeles, California
,
Milan Stevanovic
1   Department of Orthopaedic Surgery, Keck Medical Center of University of Southern California, Los Angeles, California
,
Alidad Ghiassi
1   Department of Orthopaedic Surgery, Keck Medical Center of University of Southern California, Los Angeles, California
› Author Affiliations
Further Information

Publication History

Publication Date:
29 October 2015 (online)

Abstract

Background The management of extra-articular distal radius fractures is highly variable, with no clear consensus regarding their optimal management.

Purpose To assess comparatively the biomechanical stability of Kirschner wire (K-wire) fixation, volar plating, and intramedullary nailing for unstable, extra-articular distal radius fractures with both (1) constant and (2) cyclical axial compression, simulating forces experienced during early postoperative rehabilitation.

Methods Twenty-six volar locking plate, intramedullary nail, and K-wire bone-implant constructs were biomechanically assessed using an unstable extra-articular distal radius bone model. Bone implant models were created for each type of construct. Three samples from each construct underwent compressive axial loading until fixation failure. The remaining samples from each construct underwent fatigue testing with a 50-N force for 2,000 cycles followed by repeat compressive axial loading until fixation failure.

Results Axial loading revealed the volar plate was significantly stiffer than the intramedullary nail and K-wire constructs. Both the volar plate and intramedullary nail required greater than 300 N of force for fixation failure, while the K-wire construct failed at less than 150 N. Both the volar plate and intramedullary nail demonstrated less than 1 mm of displacement during cyclic loading, while the K-wire construct displaced greater than 3 mm. Postfatigue testing demonstrated the volar plate was stiffer than the intramedullary nail and K-wire constructs, and both the volar plate and intramedullary nail required greater than 300 N of force for fixation failure while the K-wire construct failed at less than 150 N.

Conclusions Volar plating of unstable extra-articular distal radius fractures is biomechanically stiffer than K-wire and intramedullary fixation. Both the volar plate and intramedullary nail demonstrated the necessary stability and stiffness to maintain anatomic reduction during the postoperative rehabilitation period.

Clinical Relevance Both the volar plate and intramedullary nail demonstrated the necessary biomechanical stability to maintain postoperative reduction in extra-articular distal radius fractures, warranting further clinical comparison.

 
  • References

  • 1 Nana AD, Joshi A, Lichtman DM. Plating of the distal radius. J Am Acad Orthop Surg 2005; 13 (3) 159-171
  • 2 Koval K, Haidukewych GJ, Service B, Zirgibel BJ. Controversies in the management of distal radius fractures. J Am Acad Orthop Surg 2014; 22 (9) 566-575
  • 3 Costa ML, Achten J, Parsons NR , et al; DRAFFT Study Group. Percutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius: randomised controlled trial. BMJ 2014; 349: g4807
  • 4 Gradl G, Mielsch N, Wendt M , et al. Intramedullary nail versus volar plate fixation of extra-articular distal radius fractures. Two year results of a prospective randomized trial. Injury 2014; 45 (Suppl. 01) S3-S8
  • 5 Grewal R, MacDermid JC, King GJ, Faber KJ. Open reduction internal fixation versus percutaneous pinning with external fixation of distal radius fractures: a prospective, randomized clinical trial. J Hand Surg Am 2011; 36 (12) 1899-1906
  • 6 Karantana A, Downing ND, Forward DP , et al. Surgical treatment of distal radial fractures with a volar locking plate versus conventional percutaneous methods: a randomized controlled trial. J Bone Joint Surg Am 2013; 95 (19) 1737-1744
  • 7 Plate JF, Gaffney DL, Emory CL , et al. Randomized comparison of volar locking plates and intramedullary nails for unstable distal radius fractures. J Hand Surg Am 2015; 40 (6) 1095-1101
  • 8 Rozental TD, Blazar PE, Franko OI, Chacko AT, Earp BE, Day CS. Functional outcomes for unstable distal radial fractures treated with open reduction and internal fixation or closed reduction and percutaneous fixation. A prospective randomized trial. J Bone Joint Surg Am 2009; 91 (8) 1837-1846
  • 9 Wei DH, Raizman NM, Bottino CJ, Jobin CM, Strauch RJ, Rosenwasser MP. Unstable distal radial fractures treated with external fixation, a radial column plate, or a volar plate. A prospective randomized trial. J Bone Joint Surg Am 2009; 91 (7) 1568-1577
  • 10 Williksen JH, Frihagen F, Hellund JC, Kvernmo HD, Husby T. Volar locking plates versus external fixation and adjuvant pin fixation in unstable distal radius fractures: a randomized, controlled study. J Hand Surg Am 2013; 38 (8) 1469-1476
  • 11 Konstantinidis L, Helwig P, Seifert J , et al. Internal fixation of dorsally comminuted fractures of the distal part of the radius: a biomechanical analysis of volar plate and intramedullary nail fracture stability. Arch Orthop Trauma Surg 2011; 131 (11) 1529-1537
  • 12 Rozental TD, Beredjiklian PK, Bozentka DJ. Functional outcome and complications following two types of dorsal plating for unstable fractures of the distal part of the radius. J Bone Joint Surg Am 2003; 85-A (10) 1956-1960
  • 13 Willis AA, Kutsumi K, Zobitz ME, Cooney III WP. Internal fixation of dorsally displaced fractures of the distal part of the radius. A biomechanical analysis of volar plate fracture stability. J Bone Joint Surg Am 2006; 88 (11) 2411-2417
  • 14 Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 2007; 21 (5) 316-322
  • 15 Ring D, Jupiter JB, Brennwald J, Büchler U, Hastings II H. Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures. J Hand Surg Am 1997; 22 (5) 777-784
  • 16 Cross AW, Schmidt CC. Flexor tendon injuries following locked volar plating of distal radius fractures. J Hand Surg Am 2008; 33 (2) 164-167
  • 17 Lifchez SD. Flexor pollicis longus tendon rupture after volar plating of a distal radius fracture. Plast Reconstr Surg 2010; 125 (1) 21e-23e
  • 18 McFadyen I, Field J, McCann P, Ward J, Nicol S, Curwen C. Should unstable extra-articular distal radial fractures be treated with fixed-angle volar-locked plates or percutaneous Kirschner wires? A prospective randomised controlled trial. Injury 2011; 42 (2) 162-166
  • 19 Hsu LP, Schwartz EG, Kalainov DM, Chen F, Makowiec RL. Complications of K-wire fixation in procedures involving the hand and wrist. J Hand Surg Am 2011; 36 (4) 610-616
  • 20 Harley BJ, Scharfenberger A, Beaupre LA, Jomha N, Weber DW. Augmented external fixation versus percutaneous pinning and casting for unstable fractures of the distal radius—a prospective randomized trial. J Hand Surg Am 2004; 29 (5) 815-824
  • 21 Weber SC, Szabo RM. Severely comminuted distal radial fracture as an unsolved problem: complications associated with external fixation and pins and plaster techniques. J Hand Surg Am 1986; 11 (2) 157-165
  • 22 Brooks KR, Capo JT, Warburton M, Tan V. Internal fixation of distal radius fractures with novel intramedullary implants. Clin Orthop Relat Res 2006; 445 (445) 42-50
  • 23 Ilyas AM, Thoder JJ. Intramedullary fixation of displaced distal radius fractures: a preliminary report. J Hand Surg Am 2008; 33 (10) 1706-1715
  • 24 Harreld K, Li Z. Intramedullary fixation of distal radius fractures. Hand Clin 2010; 26 (3) 363-372 , vi
  • 25 Cristofolini L, Viceconti M. Mechanical validation of whole bone composite tibia models. J Biomech 2000; 33 (3) 279-288
  • 26 Cristofolini L, Viceconti M, Cappello A, Toni A. Mechanical validation of whole bone composite femur models. J Biomech 1996; 29 (4) 525-535
  • 27 van Kampen RJ, Thoreson AR, Knutson NJ, Hale JE, Moran SL. Comparison of a new intramedullary scaffold to volar plating for treatment of distal radius fractures. J Orthop Trauma 2013; 27 (9) 535-541
  • 28 Levin SM, Nelson CO, Botts JD, Teplitz GA, Kwon Y, Serra-Hsu F. Biomechanical evaluation of volar locking plates for distal radius fractures. Hand (NY) 2008; 3 (1) 55-60
  • 29 Burkhart KJ, Nowak TE, Gradl G , et al. Intramedullary nailing vs. palmar locked plating for unstable dorsally comminuted distal radius fractures: a biomechanical study. Clin Biomech (Bristol, Avon) 2010; 25 (8) 771-775
  • 30 Putnam MD, Meyer NJ, Nelson EW, Gesensway D, Lewis JL. Distal radial metaphyseal forces in an extrinsic grip model: implications for postfracture rehabilitation. J Hand Surg Am 2000; 25 (3) 469-475
  • 31 Koval KJ, Harrast JJ, Anglen JO, Weinstein JN. Fractures of the distal part of the radius. The evolution of practice over time. Where's the evidence?. J Bone Joint Surg Am 2008; 90 (9) 1855-1861
  • 32 Knox J, Ambrose H, McCallister W, Trumble T. Percutaneous pins versus volar plates for unstable distal radius fractures: a biomechanic study using a cadaver model. J Hand Surg Am 2007; 32 (6) 813-817
  • 33 Mehling I, Meier M, Schlör U, Krimmer H. Multidirectional palmar fixed-angle plate fixation for unstable distal radius fracture [in German]. Handchir Mikrochir Plast Chir 2007; 39 (1) 29-33
  • 34 Musgrave DS, Idler RS. Volar fixation of dorsally displaced distal radius fractures using the 2.4-mm locking compression plates. J Hand Surg Am 2005; 30 (4) 743-749
  • 35 Orbay JL, Fernandez DL. Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg Am 2002; 27 (2) 205-215
  • 36 Klug RA, Press CM, Gonzalez MH. Rupture of the flexor pollicis longus tendon after volar fixed-angle plating of a distal radius fracture: a case report. J Hand Surg Am 2007; 32 (7) 984-988
  • 37 Soong M, Earp BE, Bishop G, Leung A, Blazar P. Volar locking plate implant prominence and flexor tendon rupture. J Bone Joint Surg Am 2011; 93 (4) 328-335
  • 38 Pichler W, Grechenig W, Clement H, Windisch G, Tesch NP. Perforation of the third extensor compartment by the drill bit during palmar plating of the distal radius. J Hand Surg Eur Vol 2009; 34 (3) 333-335
  • 39 Tan V, Capo J, Warburton M. Distal radius fracture fixation with an intramedullary nail. Tech Hand Up Extrem Surg 2005; 9 (4) 195-201
  • 40 Dahl WJ, Nassab PF, Burgess KM , et al. Biomechanical properties of fixed-angle volar distal radius plates under dynamic loading. J Hand Surg Am 2012; 37 (7) 1381-1387
  • 41 Capo JT, Kinchelow T, Brooks K, Tan V, Manigrasso M, Francisco K. Biomechanical stability of four fixation constructs for distal radius fractures. Hand (NY) 2009; 4 (3) 272-278
  • 42 Osada D, Viegas SF, Shah MA, Morris RP, Patterson RM. Comparison of different distal radius dorsal and volar fracture fixation plates: a biomechanical study. J Hand Surg Am 2003; 28 (1) 94-104
  • 43 Rikli DA, Honigmann P, Babst R, Cristalli A, Morlock MM, Mittlmeier T. Intra-articular pressure measurement in the radioulnocarpal joint using a novel sensor: in vitro and in vivo results. J Hand Surg Am 2007; 32 (1) 67-75
  • 44 Nishiwaki M, Tazaki K, Shimizu H, Ilyas AM. Prospective study of distal radial fractures treated with an intramedullary nail. J Bone Joint Surg Am 2011; 93 (15) 1436-1441
  • 45 Schønnemann JO, Hansen TB, Søballe K. Randomised study of non-bridging external fixation compared with intramedullary fixation of unstable distal radial fractures. J Plast Surg Hand Surg 2011; 45 (4–5) 232-237
  • 46 Tan V, Bratchenko W, Nourbakhsh A, Capo J. Comparative analysis of intramedullary nail fixation versus casting for treatment of distal radius fractures. J Hand Surg Am 2012; 37 (3) 460-468.e1
  • 47 Safi A, Hart R, Těknědžjan B, Kozák T. Treatment of extra-articular and simple articular distal radial fractures with intramedullary nail versus volar locking plate. J Hand Surg Eur Vol 2013; 38 (7) 774-779
  • 48 Ilyas AM. Intramedullary fixation of distal radius fractures. J Hand Surg Am 2009; 34 (2) 341-346