J Pediatr Intensive Care 2022; 11(02): 114-119
DOI: 10.1055/s-0040-1718867
Original Article

Noninvasive Cardiac Output Monitoring Using Electrical Cardiometry and Outcomes in Critically Ill Children

1   Department of Pediatrics, The Children's Hospital of San Antonio, San Antonio, Texas, United States
,
1   Department of Pediatrics, The Children's Hospital of San Antonio, San Antonio, Texas, United States
2   Department of Pediatrics, Baylor College of Medicine, San Antonio, Texas, United States
,
Aanchal Wats
1   Department of Pediatrics, The Children's Hospital of San Antonio, San Antonio, Texas, United States
,
Mohammed Salameh
1   Department of Pediatrics, The Children's Hospital of San Antonio, San Antonio, Texas, United States
2   Department of Pediatrics, Baylor College of Medicine, San Antonio, Texas, United States
,
Arpit Agarwal
1   Department of Pediatrics, The Children's Hospital of San Antonio, San Antonio, Texas, United States
2   Department of Pediatrics, Baylor College of Medicine, San Antonio, Texas, United States
,
1   Department of Pediatrics, The Children's Hospital of San Antonio, San Antonio, Texas, United States
2   Department of Pediatrics, Baylor College of Medicine, San Antonio, Texas, United States
› Author Affiliations
Funding None.

Abstract

Cardiac output (CO) measurement is an important element of hemodynamic assessment in critically ill children and existing methods are difficult and/or inaccurate. There is insufficient literature regarding CO as measured by noninvasive electrical cardiometry (EC) as a predictor of outcomes in critically ill children. We conducted a retrospective chart review in children <21 years, admitted to our pediatric intensive care unit (PICU) between July 2018 and November 2018 with acute respiratory failure and/or shock and who were monitored with EC (ICON monitor). We collected demographic information, data on CO measurements with EC and with transthoracic echocardiography (TTE), and data on ventilator days, PICU and hospital days, inotrope score, and mortality. We analyzed the data using Chi-square and multiple linear regression analysis. Among 327 recordings of CO as measured by EC in 61 critically ill children, the initial, nadir, and median CO (L/min; median [interquartile range (IQR)]) were 3.4 (1.15, 5.6), 2.39 (0.63, 4.4), and 2.74 (1.03, 5.2), respectively. Low CO as measured with EC did not correlate well with TTE (p = 0.9). Both nadir and mean CO predicted ventilator days (p = 0.05 and 0.01, respectively), and nadir CO was correlated with peak inotrope score (correlation coefficient of –0.3). In our cohort of critically ill children with respiratory failure and/or shock, CO measured with EC did not correlate with TTE. Both nadir and median CO measured with EC predicted outcomes in critically ill children.

Contribution to the Field

Cardiac output (CO) measurement is an important element of hemodynamic assessment in critically ill children, with existing methods being difficult and/or inaccurate. Electrical cardiometry (EC) has the capability of measuring CO noninvasively. We believe that our study is the first study in the literature to demonstrate a relationship between CO measured with EC and outcomes.




Publication History

Received: 25 July 2020

Accepted: 18 September 2020

Article published online:
19 November 2020

© 2020. Thieme. All rights reserved.

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany

 
  • References

  • 1 Massé L, Antonacci M. Low cardiac output syndrome: identification and management. Crit Care Nurs Clin North Am 2005; 17 (04) 375-383 , x
  • 2 Chandler HK, Kirsch R. Management of the Low Cardiac output Syndrome following surgery for congenital heart disease. Curr Cardiol Rev 2016; 12 (02) 107-111
  • 3 Swan HJ, Ganz W, Forrester J, Marcus H, Diamond G, Chonette D. Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter. N Engl J Med 1970; 283 (09) 447-451
  • 4 Mehta Y, Arora D. Newer methods of cardiac output monitoring. World J Cardiol 2014; 6 (09) 1022-1029
  • 5 Sangkum L, Liu GL, Yu L, Yan H, Kaye AD, Liu H. Minimally invasive or noninvasive cardiac output measurement: an update. J Anesth 2016; 30 (03) 461-480
  • 6 Narula J, Chauhan S, Ramakrishnan S, Gupta SK. Electrical cardiometry: a reliable solution to cardiac output estimation in children with structural heart disease. J Cardiothorac Vasc Anesth 2017; 31 (03) 912-917
  • 7 Sandham JD, Hull RD, Brant RF. Canadian Critical Care Clinical Trials Group. et al. A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients. N Engl J Med 2003; 348 (01) 5-14
  • 8 Peeters Y, Bernards J, Mekeirele M, Hoffmann B, De Raes M, Malbrain ML. Hemodynamic monitoring: to calibrate or not to calibrate? Part 1--calibrated techniques. Anaesthesiol Intensive Ther 2015; 47 (05) 487-500
  • 9 Mercado P, Maizel J, Beyls C. et al. Transthoracic echocardiography: an accurate and precise method for estimating cardiac output in the critically ill patient. Crit Care 2017; 21 (01) 136
  • 10 Jozwiak M, Mercado P, Teboul JL. et al. What is the lowest change in cardiac output that transthoracic echocardiography can detect?. Crit Care 2019; 23 (01) 116
  • 11 Noninvasive Cardiac Output Electrical Cardiometry. Available at: www.osypkamed.com/sites/default/files/public_resources/C2_C3_Brochure_EN_2014_A4_online_0.pdf. Accessed October 4, 2020
  • 12 Moshkovitz Y, Kaluski E, Milo O, Vered Z, Cotter G. Recent developments in cardiac output determination by bioimpedance: comparison with invasive cardiac output and potential cardiovascular applications. Curr Opin Cardiol 2004; 19 (03) 229-237
  • 13 Summers RL, Shoemaker WC, Peacock WF, Ander DS, Coleman TG. Bench to bedside: electrophysiologic and clinical principles of noninvasive hemodynamic monitoring using impedance cardiography. Acad Emerg Med 2003; 10 (06) 669-680
  • 14 Marik PE, Baram M. Noninvasive hemodynamic monitoring in the intensive care unit. Crit Care Clin 2007; 23 (03) 383-400
  • 15 Teboul JL, Saugel B, Cecconi M. et al. Less invasive hemodynamic monitoring in critically ill patients. Intensive Care Med 2016; 42 (09) 1350-1359
  • 16 Yoshida A, Kaji T, Yamada H. et al. Measurement of hemodynamics immediately after vaginal delivery in healthy pregnant women by electrical cardiometry. J Med Invest 2019; 66 (1.2): 75-80
  • 17 Rauch R, Welisch E, Lansdell N. et al. Non-invasive measurement of cardiac output in obese children and adolescents: comparison of electrical cardiometry and transthoracic Doppler echocardiography. J Clin Monit Comput 2013; 27 (06) 187-193
  • 18 Noori S, Drabu B, Soleymani S, Seri I. Continuous non-invasive cardiac output measurements in the neonate by electrical velocimetry: a comparison with echocardiography. Arch Dis Child Fetal Neonatal Ed 2012; 97 (05) F340-F343
  • 19 Grollmuss O, Gonzalez P. Non-invasive cardiac output measurement in low and very low birth weight infants: a method comparison. Front Pediatr 2014; 2 (16) 16
  • 20 Grollmuss O, Demontoux S, Capderou A, Serraf A, Belli E. Electrical velocimetry as a tool for measuring cardiac output in small infants after heart surgery. Intensive Care Med 2012; 38 (06) 1032-1039
  • 21 Wernovsky G, Wypij D, Jonas RA. et al. Postoperative course and hemodynamic profile after the arterial switch operation in neonates and infants. A comparison of low-flow cardiopulmonary bypass and circulatory arrest. Circulation 1995; 92 (08) 2226-2235
  • 22 Kumar M, Sharma R, Sethi SK. et al. Vasoactive Inotrope Score as a tool for clinical care in children post cardiac surgery. Indian J Crit Care Med 2014; 18 (10) 653-658
  • 23 Zhang Y, Wang Y, Shi J, Hua Z, Xu J. Cardiac output measurements via echocardiography versus thermodilution: a systematic review and meta-analysis. PLoS One 2019; 14 (10) e0222105
  • 24 Jiang NN, Wang DY, Li F, Xie WG. [Clinical significance of pulse contour cardiac output monitoring technology in guiding fluid replacement during shock stage of extensive burn] (in Chinese). Zhonghua Shao Shang Za Zhi 2019; 35 (06) 434-440
  • 25 Aslan N, Yildizdas D, Horoz OO. et al. Comparison of cardiac output and cardiac index values measured by critical care echocardiography with the values measured by pulse index continuous cardiac output (PiCCO) in the pediatric intensive care unit:a preliminary study. Ital J Pediatr 2020; 46 (01) 47
  • 26 Wurzer P, Branski LK, Jeschke MG. et al. Transpulmonary thermodilution versus transthoracic echocardiography for cardiac output measurements in severely burned children. Shock 2016; 46 (03) 249-253
  • 27 Van Wyk L, Smith J, Lawrenson J, de Boode WP. Agreement of cardiac output measurements between bioreactance and transthoracic echocardiography in preterm infants during the transitional phase: a single-centre, prospective study. Neonatology 2020; 117: 271-278
  • 28 Boet A, Jourdain G, Demontoux S, De Luca D. Stroke volume and cardiac output evaluation by electrical cardiometry: accuracy and reference nomograms in hemodynamically stable preterm neonates. J Perinatol 2016; 36 (09) 748-752
  • 29 Hsu KH, Wu TW, Wu IH. et al. Electrical cardiometry to monitor cardiac output in preterm infants with patent ductus arteriosus: a comparison with echocardiography. Neonatology 2017; 112 (03) 231-237