Klin Monbl Augenheilkd 2022; 239(12): 1457-1461
DOI: 10.1055/a-1535-1785
Der interessante Fall

Successful Bilateral Exchange of Multifocal IOLs 7 Years after Cataract Surgery due to Patient Dissatisfaction

Erfolgreicher bilateraler Austausch von multifokalen IOLs 7 Jahre nach der Kataraktoperation aufgrund von Unzufriedenheit des Patienten
Department of Ophthalmology, Saarland University Medical Center, Homburg, Germany
,
Sabine Lepper
Department of Ophthalmology, Saarland University Medical Center, Homburg, Germany
,
Loay Daas
Department of Ophthalmology, Saarland University Medical Center, Homburg, Germany
,
Department of Ophthalmology, Saarland University Medical Center, Homburg, Germany
› Author Affiliations

History

We report on a case of a 56-year-old male complaining of an unsatisfactory visual outcome with visual artifacts such as halos and dysphotopsia in both eyes since a cataract surgery with aspheric refractive multifocal lens implantation (AMO ReZoom NXG1, + 19.5 D in both eyes) 7 years earlier. The refraction in the eyes before the intraocular lens (IOL) exchange was + 0.5/− 1.00/13° and + 0.0/− 1.00/113° in the right and left eye, respectively.



Publication History

Received: 22 January 2021

Accepted: 21 June 2021

Article published online:
15 September 2021

© 2021. Thieme. All rights reserved.

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany

 
  • References

  • 1 Geggel HS. Simplified technique for acrylic intraocular lens explantation. Ophthalmic Surg Lasers Imaging 2000; 31: 506-507
  • 2 Mehta JS, Wilkins MR, Gartry DS. Explantation of an acrylic Acrysof intraocular lens without wound enlargement. Acta Ophthalmol Scand 2005; 83: 262-263
  • 3 Cochener B, Lafuma A, Khoshnood B. et al. Comparison of outcomes with multifocal intraocular lenses: a meta-analysis. Clin Ophthalmol 2011; 5: 45-56
  • 4 De Vries NE, Nuijts RMMA. Multifocal intraocular lenses in cataract surgery: literature review of benefits and side effects. J Cataract Refract Surg 2013; 39: 268-278
  • 5 Kohnen T, Klaproth OK, Bühren J. Effect of intraocular lens asphericity on quality of vision after cataract removal: an intraindividual comparison. Ophthalmology 2009; 116: 1697-1706
  • 6 Cillino S, Casuccio A, Di Pace F. et al. One-year outcomes with new-generation multifocal intraocular lenses. Ophthalmology 2008; 115: 1508-1516
  • 7 Alfonso JF, Fernández-Vega L, Puchades C. et al. Intermediate visual function with different multifocal intraocular lens models. J Cataract Refract Surg 2010; 36: 733-739
  • 8 Alio JL, Plaza-Puche AB, Férnandez-Buenaga R. et al. Multifocal intraocular lenses: An overview. Surv Ophthalmol 2017; 62: 611-634
  • 9 Rosen E, Alió JL, Dick HB. et al. Efficacy and safety of multifocal intraocular lenses following cataract and refractive lens exchange: Metaanalysis of peer-reviewed publications. J Cataract Refract Surg 2016; 42: 310-328
  • 10 Richter-Mueksch S, Weghaupt H, Skorpik C. et al. Reading performance with a refractive multifocal and a diffractive bifocal intraocular lens. J Cataract Refract Surg 2002; 28: 1957-1963
  • 11 Braga-Mele R, Chang D, Dewey S. et al. Multifocal intraocular lenses: relative indications and contraindications for implantation. J Cataract Refract Surg 2014; 40: 313-322
  • 12 Mesci C, Erbil H, Özdöker L. et al. Visual acuity and contrast sensitivity function after accommodative and multifocal intraocular lens implantation. Eur J Ophthalmol 2010; 20: 90-100
  • 13 Auffarth GU, Moraru O, Munteanu M. et al. European, multicenter, prospective, non-comparative clinical evaluation of an extended depth of focus intraocular lens. J Refract Surg 2020; 36: 426-434
  • 14 Alio JL, Simonov A, Plaza-Puche AB. et al. Visual outcomes and accommodative response of the lumina accommodative intraocular lens. Am J Ophthalmol 2016; 164: 37-48
  • 15 Soda M, Yaguchi S. Effect of decentration on the optical performance in multifocal intraocular lenses. Ophthalmologica 2012; 227: 197-204
  • 16 Hayashi K, Hayashi H, Nakao F. Correlation between pupillary size and intraocular lens decentration and visual acuity of a zonal-progressive multifocal lens and a monofocal lens. Ophthalmology 2001; 108: 2011-2017
  • 17 De Vries NE, Webers CAB, Touwslager WRH. et al. Dissatisfaction after implantation of multifocal intraocular lenses. J Cataract Refract Surg 2011; 37: 859-865
  • 18 Alió JL, Elkady B, Ortiz D. et al. Clinical outcomes and intraocular optical quality of a diffractive multifocal intraocular lens with asymmetrical light distribution. J Cataract Refract Surg 2008; 34: 942-948
  • 19 Leaming DV. Practice styles and preferences of ASCRS members–2000 survey. J Cataract Refract Surg 2001; 27: 948-955
  • 20 Doren GS, Stern GA, Driebe WT. Indications for and results of intraocular lens explantation. J Cataract Refract Surg 1992; 18: 79-85
  • 21 Jones JJ, Jones YJ, Jin GJ. Indications and outcomes of intraocular lens exchange during a recent 5-year period. Am J Ophthalmol 2013; 157: 154-162
  • 22 El Awady HE, Ghanem AA. Secondary piggyback implantation versus IOL exchange for symptomatic pseudophakic residual ametropia. Graefes Arch Clin Exp Ophthalmol 2013; 251: 1861-1866
  • 23 Gatzioufas Z, Oscald A, Schroeder AC. et al. A serious refractive multifocal intraocular lens complication in Meniereʼs disease. Optom Vis Sci 2010; 87: 448-449
  • 24 Kamiya K, Hayashi K, Shimizu K. et al. Multifocal intraocular lens explantation: a case series of 50 eyes. Am J Ophthalmol 2014; 158: 215-220
  • 25 Van der Mooren M, Steinert R, Tyson F. et al. Explanted multifocal intraocular lenses. J Cataract Refract Surg 2015; 41: 873-877
  • 26 Fernández-Buenaga R, Alió JL. Intraocular lens explantation after cataract surgery: indications, results, and explantation techniques. Asia Pac J Ophthalmol 2017; 6: 372-380
  • 27 Bhaumik A, Mitra S. A simple technique of intraocular lenses explantation for single-piece foldable lenses. Indian J Ophthalmol 2017; 65: 1428-1430