J Hand Microsurg 2020; 12(S 01): S45-S49
DOI: 10.1055/s-0038-1676871
Case Report

Intra-arterial Foreign Body following Radial Artery Cannulation Requiring Microsurgical Removal: Case Report and Review of the Literature

Shawn D. Feinstein
1   Department of Orthopaedics, University of North Carolina, Chapel Hill, North Carolina, United States
,
Reid W. Draeger
1   Department of Orthopaedics, University of North Carolina, Chapel Hill, North Carolina, United States
› Author Affiliations
Funding None.

Abstract

We report the case of a pediatric patient who underwent intra-arterial exploration and removal of foreign body after an arterial catheter cannula inadvertently fractured during removal and a fragment remained within the radial artery. The fragment was visualized using fluoroscopy intraoperatively and was successfully removed from the common digital artery to the index finger where it had migrated. We present the case as a rare complication of an exceedingly common procedure with a timely response to avoid further complication.



Publication History

Article published online:
24 December 2018

© .

Thieme Medical and Scientific Publishers Private Ltd.
A-12, Second Floor, Sector -2, NOIDA -201301, India

 
  • References

  • 1 Gardner RM. Direct arterial pressure monitoring. Curr Anaesth Crit Care 1990; 1 (04) 239-246
  • 2 Scheer B, Perel A, Pfeiffer UJ. Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine. Crit Care 2002; 6 (03) 199-204
  • 3 Nuttall G, Burckhardt J, Hadley A. et al. Surgical and patient risk factors for severe arterial line complications in adults. Anesthesiology 2016; 124 (03) 590-597
  • 4 Durie M, Beckmann U, Gillies DM. Incidents relating to arterial cannulation as identified in 7,525 reports submitted to the Australian incident monitoring study (AIMS-ICU).. Anaesth Intensive Care 2002; 30 (01) 60-65
  • 5 Luo C-F, Mao CC, Su BC, Yu HP. An iatrogenic complication of radial artery cannulation. Acta Anaesthesiol Taiwan 2010; 48 (03) 145-147
  • 6 Moody C, Bhimarasetty C, Deshmukh S. Ultrasound guided location and removal of retained arterial cannula fragment. Anaesthesia 2009; 64 (03) 338-339
  • 7 Shah US, Downing R, Davis I. An iatrogenic arterial foreign body. Br J Anaesth 1996; 77 (03) 430-431
  • 8 Ferguson E, Baumgartner P, Hamilton M. Accidental transection of radial [correction of radical] artery cannula. Anaesth Intensive Care 2005; 33 (01) 142-143
  • 9 Brown M. Another complication of arterial cannulation. Anaesthesia 1991; 46 (04) 326-326
  • 10 Nebel C, Kulwicki A, Muck P. An unusual arterial line complication. Am Surg 2009; 75 (11) 1148-1149
  • 11 Mayne D, Kharwar F. Another complication of radial artery cannulation. Anaesthesia 1997; 52 (01) 89-90
  • 12 Egwu VN, Sadr B. Radial arterial foreign body as a cause of wrist pain. Anesth Analg 1987; 66 (10) 1058-1059
  • 13 Ball DR, Stott SA, Rouse R. Locating an arterial foreign body by ultrasonography. Br J Anaesth 1996; 77 (06) 811-811
  • 14 Kim MS, Horton JA. Intra-arterial foreign body retrieved using endoscopic biopsy forceps. Radiology 1983; 149 (02) 597