J Wrist Surg 2021; 10(05): 440-457
DOI: 10.1055/s-0041-1723793
Survey or Meta-analysis

Interventions for Distal Radius Fractures: A Meta-analysis of Comparison Studies

Julia Beyer
1   Department of Orthopaedic Surgery, University of Toledo Medical Center, Toledo, Ohio
,
Emily Wynkoop
1   Department of Orthopaedic Surgery, University of Toledo Medical Center, Toledo, Ohio
,
1   Department of Orthopaedic Surgery, University of Toledo Medical Center, Toledo, Ohio
,
Nabil A. Ebraheim
1   Department of Orthopaedic Surgery, University of Toledo Medical Center, Toledo, Ohio
› Author Affiliations

Abstract

Background Distal radius fractures are one of the most frequent orthopaedic injuries. There are many effective treatment methods, such as volar plate, dorsal plate, percutaneous pins, external fixation, and casting; however, comparison of the treatment outcomes has not been thoroughly investigated. Our purpose is to determine if volar plating is the superior treatment method for distal radius fractures. We will address this through the following questions: First, is volar plating superior to dorsal plating, percutaneous pins, external fixation, or casting in terms of reported complications? Second, does volar plating produce superior functional outcomes to dorsal plating, percutaneous pins, external fixation, or casting? Third, are the radiographic outcomes superior for volar plating when compared with dorsal plating, percutaneous pins, external fixation, or casting?

Methods MEDLINE, Academic Search Ultimate, Academic Search Complete, CINAHL Plus, and JSTOR databases, as well as manual search, were used to identify papers comparing complications and functional results of volar plating to other treatment methods for distal radius fractures published after the year 2000. Complication data and function scores were recorded. Risk of bias was assessed using the Cochrane Risk of Bias Tool and data was analyzed for meta-analysis using Cochrane ReviewManager software.

Results Compared with dorsal plate, volar plate performed significantly better in Gartland and Werley score. Volar plating outperformed percutaneous pins for loss of reduction, infection, Disabilities of the Arm, Shoulder, and Hand (DASH) score, and ulnar deviation. Loss of reduction, malunion, Patient Related Wrist Evaluation (PRWE) score, DASH score, grip strength, ulnar deviation, and supination were significantly better for volar plating when compared with casting. When compared with external fixation, volar plating had significantly less cases of infection, lower QuickDASH score, and higher range of motion for flexion, pronation, and supination. All other complication and functional outcomes were not significantly different.

Conclusions Distal radius fractures treated with volar plating showed relatively better measures of complications, function scores, and range of motion than other treatment methods; however, there was no significant difference in healing time when compared with percutaneous pins. More studies are needed to compare the rest of the treatment methods with each other.



Publication History

Received: 18 June 2020

Accepted: 29 December 2020

Article published online:
09 February 2021

© 2021. Thieme. All rights reserved.

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

 
  • References

  • 1 ÇİÇEKLİ Ö, ŞÜKÜR E, KOCHAİ A, BAYAM L, BİNGÖL İ, ÖZDEMİR U. Comparison of 2-year clinical and radiological outcomes between volar plating and external fixation with additional K-wires for AO Type C distal radius fractures. Turk J Med Sci 2019; 49 (05) 1418-1425
  • 2 Duramaz A, Bilgili MG, Karaali E, Bayram B, Ziroğlu N, Kural C. Volar locking plate versus K-wire-supported external fixation in the treatment of AO/ASIF type C distal radius fractures: A comparison of functional and radiological outcomes. Ulus Travma Acil Cerrahi Derg 2018; 24 (03) 255-262
  • 3 Jakubietz MG, Gruenert JG, Jakubietz RG. Palmar and dorsal fixed-angle plates in AO C-type fractures of the distal radius: is there an advantage of palmar plates in the long term?. J Orthop Surg Res 2012; 7 (01) 8
  • 4 Roh YH, Lee BK, Baek JR, Noh JH, Gong HS, Baek GH. A randomized comparison of volar plate and external fixation for intra-articular distal radius fractures. J Hand Surg Am 2015; 40 (01) 34-41
  • 5 Rozental TD, Blazar PE, Franko OI, Chacko AT, Earp BE, Day CS. Functional outcomes for unstable distal radial fractures treated with open reduction and internal fixation or closed reduction and percutaneous fixation. A prospective randomized trial. J Bone Joint Surg Am 2009; 91 (08) 1837-1846
  • 6 Toon DH, Premchand RAX, Sim J, Vaikunthan R. Outcomes and financial implications of intra-articular distal radius fractures: a comparative study of open reduction internal fixation (ORIF) with volar locking plates versus nonoperative management. J Orthop Traumatol 2017; 18 (03) 229-234
  • 7 Brennan SA, Kiernan C, Beecher S. et al. Volar plate versus k-wire fixation of distal radius fractures. Injury 2016; 47 (02) 372-376
  • 8 Chan YH, Foo TL, Yeo CJ, Chew WY. Comparison between cast immobilization versus volar locking plate fixation of distal radius fractures in active elderly patients, the Asian perspective. Hand Surg 2014; 19 (01) 19-23
  • 9 Costa ML, Achten J, Parsons NR. et al; DRAFFT Study Group. Percutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius: randomised controlled trial. BMJ 2014; 349: g4807
  • 10 Hull P, Baraza N, Gohil M. et al. Volar locking plates versus K-wire fixation of dorsally displaced distal radius fractures--a functional outcome study. J Trauma 2011; 70 (06) E125-E128
  • 11 Jeudy J, Steiger V, Boyer P, Cronier P, Bizot P, Massin P. Treatment of complex fractures of the distal radius: a prospective randomised comparison of external fixation ‘versus’ locked volar plating. Injury 2012; 43 (02) 174-179
  • 12 Krustins U, Krustins J, Bringina D, Laurane K, Jumtins A. Comparison of volar locking plates with external fixation and K-wires in arthroscopically assisted intra-articular distal radial fracture fixation. J Hand Surg Eur Vol 2020; 45 (04) 333-338
  • 13 Kumbaraci M, Kucuk L, Karapinar L, Kurt C, Coskunol E. Retrospective comparison of external fixation versus volar locking plate in the treatment of unstable intra-articular distal radius fractures. Eur J Orthop Surg Traumatol 2014; 24 (02) 173-178
  • 14 Lee YS, Wei TY, Cheng YC, Hsu TL, Huang CR. A comparative study of Colles' fractures in patients between fifty and seventy years of age: percutaneous K-wiring versus volar locking plating. Int Orthop 2012; 36 (04) 789-794
  • 15 Maire N, Lebailly F, Zemirline A, Hariri A, Facca S, Liverneaux P. Prospective continuous study comparing intrafocal cross-pinning HK2(®) with a locking plate in distal radius fracture fixation. Chir Main 2013; 32 (01) 17-24
  • 16 Mulders MAM, Walenkamp MMJ, van Dieren S, Goslings JC, Schep NWL. VIPER Trial Collaborators. Volar plate fixation versus plaster immobilization in acceptably reduced extra-articular distal radial fractures: a multicenter randomized controlled trial. J Bone Joint Surg Am 2019; 101 (09) 787-796
  • 17 Saving J, Enocson A, Ponzer S, Mellstrand Navarro C. External fixation versus volar locking plate for unstable dorsally displaced distal radius fractures-a 3-year follow-up of a randomized controlled study. J Hand Surg Am 2019; 44 (01) 18-26
  • 18 Shukla R, Jain RK, Sharma NK, Kumar R. External fixation versus volar locking plate for displaced intra-articular distal radius fractures: a prospective randomized comparative study of the functional outcomes. J Orthop Traumatol 2014; 15 (04) 265-270
  • 19 Yu X, Yu Y, Shao X, Bai Y, Zhou T. Volar locking plate versus external fixation with optional additional K-wire for treatment of AO type C2/C3 fractures: a retrospective comparative study. J Orthop Surg Res 2019; 14 (01) 271
  • 20 Zhou Y, Zhu Y, Zhang X, Tian D, Zhang B. Comparison of radiographic and functional results of die-punch fracture of distal radius between volar locking plating (VLP) and external fixation (EF). J Orthop Surg Res 2019; 14 (01) 373
  • 21 Abe Y, Tokunaga S, Moriya T. Management of intra-articular distal radius fractures: volar or dorsal locking plate-which has fewer complications?. Hand (N Y) 2017; 12 (06) 561-567
  • 22 Chou YC, Chen AC, Chen CY, Hsu YH, Wu CC. Dorsal and volar 2.4-mm titanium locking plate fixation for AO type C3 dorsally comminuted distal radius fractures. J Hand Surg Am 2011; 36 (06) 974-981
  • 23 Kumar S, Khan AN, Sonanis SV. Radiographic and functional evaluation of low profile dorsal versus volar plating for distal radius fractures. J Orthop 2016; 13 (04) 376-382
  • 24 Lozano-Calderón SA, Doornberg JN, Ring D. Retrospective comparison of percutaneous fixation and volar internal fixation of distal radius fractures. Hand (N Y) 2008; 3 (02) 102-110
  • 25 Rein S, Schikore H, Schneiders W, Amlang M, Zwipp H. Results of dorsal or volar plate fixation of AO type C3 distal radius fractures: a retrospective study. J Hand Surg Am 2007; 32 (07) 954-961
  • 26 Ruch DS, Papadonikolakis A. Volar versus dorsal plating in the management of intra-articular distal radius fractures. J Hand Surg Am 2006; 31 (01) 9-16
  • 27 Wichlas F, Haas NP, Disch A, Machó D, Tsitsilonis S. Complication rates and reduction potential of palmar versus dorsal locking plate osteosynthesis for the treatment of distal radius fractures. J Orthop Traumatol 2014; 15 (04) 259-264
  • 28 Goehre F, Otto W, Schwan S, Mendel T, Vergroesen PP, Lindemann-Sperfeld L. Comparison of palmar fixed-angle plate fixation with K-wire fixation of distal radius fractures (AO A2, A3, C1) in elderly patients. J Hand Surg Eur Vol 2014; 39 (03) 249-257
  • 29 Gradl G, Gradl G, Wendt M, Mittlmeier T, Kundt G, Jupiter JB. Non-bridging external fixation employing multiplanar K-wires versus volar locked plating for dorsally displaced fractures of the distal radius. Arch Orthop Trauma Surg 2013; 133 (05) 595-602
  • 30 Hammer OL, Clementsen S, Hast J, Šaltytė Benth J, Madsen JE, Randsborg PH. Volar locking plates versus augmented external fixation of intra-articular distal radial fractures: functional results from a randomized controlled trial. J Bone Joint Surg Am 2019; 101 (04) 311-321
  • 31 Huang YY, Lin TY, Chen CH, Chou YC, Su CY. Surgical outcomes of elderly patients aged more than 80 years with distal radius fracture: comparison of external fixation and locking plate. BMC Musculoskelet Disord 2020; 21 (01) 91
  • 32 Bartl C, Stengel D, Bruckner T, Gebhard F. ORCHID Study Group. The treatment of displaced intra-articular distal radius fractures in elderly patients. Dtsch Arztebl Int 2014; 111 (46) 779-787
  • 33 Mellstrand Navarro C, Ahrengart L, Törnqvist H, Ponzer S. Volar locking plate or external fixation with optional addition of K-wires for dorsally displaced distal radius fractures: a randomized controlled study. J Orthop Trauma 2016; 30 (04) 217-224
  • 34 Williksen JH, Frihagen F, Hellund JC, Kvernmo HD, Husby T. Volar locking plates versus external fixation and adjuvant pin fixation in unstable distal radius fractures: a randomized, controlled study. J Hand Surg Am 2013; 38 (08) 1469-1476
  • 35 Arora R, Lutz M, Deml C, Krappinger D, Haug L, Gabl M. A prospective randomized trial comparing nonoperative treatment with volar locking plate fixation for displaced and unstable distal radial fractures in patients sixty-five years of age and older. J Bone Joint Surg Am 2011; 93 (23) 2146-2153
  • 36 Martinez-Mendez D, Lizaur-Utrilla A, de-Juan-Herrero J. Intra-articular distal radius fractures in elderly patients: a randomized prospective study of casting versus volar plating. J Hand Surg Eur Vol 2018; 43 (02) 142-147
  • 37 Saving J, Severin Wahlgren S, Olsson K. et al. Nonoperative treatment compared with volar locking plate fixation for dorsally displaced distal radial fractures in the elderly: a randomized controlled trial. J Bone Joint Surg Am 2019; 101 (11) 961-969
  • 38 Moher D, Liberati A, Tetzlaff J, Altman DG. PRISMA Group. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med 2009; 6 (07) e1000097 DOI: 10.1371/journal.pmed1000097.
  • 39 Sterne JAC, Savović J, Page MJ. et al. RoB 2: a revised tool for assessing risk of bias in randomised trials. BMJ 2019; 366: l4898
  • 40 Manager R. (RevMan) [Computer program], Version 5.3. Copenhagen: The Nordic Cochrane Centre, The Cochrane Collaboration. 2014
  • 41 Sharma H, Khare GN, Singh S, Ramaswamy AG, Kumaraswamy V, Singh AK. Outcomes and complications of fractures of distal radius (AO type B and C): volar plating versus nonoperative treatment [published correction appears in J Orthop Sci.. 2014 Jul;19(4):545] J Orthop Sci 2014; 19 (04) 537-544