J Am Acad Audiol
DOI: 10.1055/a-2156-4393
Research Article

Measuring objective and subjective intelligibility using speech materials from the Tracking of Noise Tolerance (TNT) test

Francis Kuk
1   Widex Hearing Aid Company, Lisle, United States
,
Christopher Slugocki
2   Widex, ORCA, Lisle, United States
,
Petri Korhonen
3   Widex Hearing Aid Company, Lisle, United States
› Author Affiliations

Background: The results of tests measuring objective speech intelligibility are similar to those measuring subjective speech intelligibility using speech materials with minimal context. It is unclear if such is the case with contextual materials. Purpose: To compare objective and subjective intelligibility difference (OSID) between normal-hearing (NH) and hearing-impaired (HI) listeners in the unaided and aided modes using speech materials adapted from the Tracking of Noise Tolerance (TNT) test. Research Design: Single-blind within-subjects design. Study sample: Twenty-four NH and 17 HI older adults. Data collection and analysis: Listeners completed the objective and subjective intelligibility measures at 75 dB SPL and 82 dB SPL speech input levels. Five signal-to-noise ratios (SNR) were tested to generate the objective and subjective speech intelligibility performance-intensity (P-I) functions. Both NH and HI listeners were tested in the unaided mode. The HI listeners were also tested using their own hearing aids (HAs). Objective and subjective speech-reception thresholds at a 50% criterion (SRT50s) were estimated from each individual P-I function. The difference between the objective SRT50 and subjective SRT50 was used to estimate OSID. Results: Objective and subjective SRT50s were significantly better in NH than in HI listeners (χ2(1) = 26.29, p < 0.001) at each speech input level in the unaided mode. However, there was a significant interaction between listener group and intelligibility type (χ2(1) = 9.43, p = 0.002) where SRT50s were lower for subjective than objective P-I functions only in the HI group. The SRT50s of HI listeners were also affected by hearing mode, where both objective and subjective intelligibility was improved when HI listeners were tested while wearing their own HAs. In general, objective and subjective SRT50s showed moderate-to-strong correlations across most combinations of listener groups and test conditions (r = 0.59–0.86, p < 0.01) except for HI listeners tested with their own HAs (r = 0.39, p = 0.128). Conclusions: Similar objective and subjective intelligibility was observed in NH listeners but better subjective intelligibility than objective intelligibility was noted in HI listeners when tested in the unaided and aided modes.



Publication History

Received: 20 March 2023

Accepted after revision: 04 August 2023

Accepted Manuscript online:
18 August 2023

© . American Academy of Audiology. This article is published by Thieme.

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor , NY 10001 New York, USA