Endoscopy 1973; 5(4): 194-199
DOI: 10.1055/s-0028-1098240
Original Contributions

© Georg Thieme Verlag, Stuttgart

Gastroscopy in the Estimation of Maximal Acid Output

Schätzung des maximalen Säure-Outputs in der GastroskopieH. Petersen, J. Myren
  • Gastroenterological Research Laboratory, Dept. IX, Ullevaal University Hospital, Oslo, Norway
Further Information

Publication History

Publication Date:
08 December 2008 (online)

Summary

The maximal acid output (MAO) was suggested from the endoscopic appearance of the stomach in 105 consecutive patients. The endoscopist had no knowledge of the patient. – A significant correlation (r = 0.58) was found between the suggested MAO and the MAO measured in a subsequent secretory test. The comparison of measured and suggested values for MAO and the gradings of the endoscopic characteristics, showed that the gastroscopic evaluation of mucosal foldings, injection, mucus covering and artificial bleeding, is of value in predicting acid secretory capacity.

Zusammenfassung

Der maximale Säure-Output (MAO) wurde auf Grund des makroskopischen Aspektes bei 105 Pat. geschätzt. Hierbei fand sich eine signifikante Korrelation (r = 0,58) zwischen geschätzter und tatsächlich ermittelter Säureleistung. Die Schleimhautfältelung, eine Injektion der Schleimhaut, der Schleimüberzug und eine artefizielle Blutungsneigung waren die wichtigsten Kriterien bei der Vorhersage der Sekretionskapazität.