J Am Acad Audiol 2000; 11(01): 46-51
DOI: 10.1055/s-0042-1748007
Original Article

The CON-SOT-LOT Test for Nonorganic Hearing Loss

Jeffrey S. Martin
Brigham and Woman's Hospital, Division of Audiology, Boston, Massachusetts
,
Frederick N. Martin
Department of Communication Science and Disorders, The University of Texas at Austin, Austin, Texas
,
Craig A. Champlin
Department of Communication Science and Disorders, The University of Texas at Austin, Austin, Texas
› Author Affiliations

Abstract

The efficacy of a screening procedure for detecting nonorganic hearing loss using standard audiometric instrumentation was examined. Thirty normal-hearing subjects' responses to continuous and standard and lengthened off-time pulsed tones, using an ascending-descending method, were compared. Subjects were asked to respond to test stimuli in normal-hearing and simulated hearing loss conditions. Data show that there are clinical and statistical differences between subjects' response patterns in the normal-hearing condition as compared to the feigned hearing loss condition. The procedure is offered as a simple method of screening for nonorganic hearing loss.

Abbreviations: A-D = ascending-descending, ANOVA = analysis of variance, CON = continuous tone, LOT = lengthened off-time pulsed tone, MML = modified method of limits, NOHL = nonorganic hearing loss, STL = simulated threshold level, SOT = standard off-time pulsed tone



Publication History

Article published online:
05 April 2022

© 2000. American Academy of Audiology. This article is published by Thieme.

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

 
  • REFERENCES

  • American National Standards Institute. (1996). American National Standard Specifications for Audiometers. (ANSI S3.6–1996). New York: ANSI.
  • American National Standards Institute. (1991). American National Standard Criteria for Permissible Ambient Noise Levels during Audiometric Testing. (ANSI S3.1–1993). New York: ANSI.
  • Chaiklin JB. (1990). A descending LOT-Békésy screening test for functional hearing loss. J Speech Hear Disord 55:67–74.
  • Cherry R, Ventry IM. (1976). The ascending-descending gap: a tool for identifying a suprathreshold response. J Aud Res 16:281–287.
  • Harris DA. (1958). A rapid and simple technique for the detection of non-organic hearing loss. Arch Otolaryngol 68:758–760.
  • Hattler KW. (1968). The Type V Békésy pattern: the effects of loudness memory. J Speech Hear Res 11:567–575.
  • Hattler KW. (1970). Lengthened off time: a self-recording screening device for nonorganicity. J Speech Hear Disord 35:113–122.
  • Hood WH, Campbell RA, Hutton CL. (1964). An evaluation of the Békésy ascending descending gap. J Speech Hear Res 7:123–132.
  • Jerger J, Herer G. (1961). An unexpected dividend in Békésy audiometry. J Speech Hear Disord 26:390–391.
  • Lankford JE, Meissner WA. (1977). The manual lot test. J Am Audiol Soc 2:219–222.
  • Martin FN, Champlin CA, Chambers JA. (1998a). Seventh survey of audiometric practices in the United States. J Am Acad Audiol 9:95–104.
  • Martin FN, Champlin CA, Marchbanks TP. (1998b). A varying intensity speech test for simulated hearing loss. Am J Audiol 7:39–44.
  • Mordaunt KM, Martin FN. (1976). Effects of duty cycle on the loudness of pulsed and continuous tones. J Aud Res 16:171–175.
  • Woodford C, Harris G, Marquette ML, Perry L, Barnhart M. (1997). A screening test for pseudohypacusis. Hear Rev 11(4):23–26.