Eur J Pediatr Surg 2017; 27(01): 002-006
DOI: 10.1055/s-0036-1587585
Original Article
Georg Thieme Verlag KG Stuttgart · New York

The Minimally Invasive Repair of Pectus Excavatum Using a Subxiphoid Incision

Joanna L. Gould
1   Department of Surgery, Children's Mercy Hospital, Kansas City, Missouri, United States
,
Ronald J. Sharp
1   Department of Surgery, Children's Mercy Hospital, Kansas City, Missouri, United States
,
Shawn David St. Peter
1   Department of Surgery, Children's Mercy Hospital, Kansas City, Missouri, United States
,
Charles L. Snyder
1   Department of Surgery, Children's Mercy Hospital, Kansas City, Missouri, United States
,
David Juang
1   Department of Surgery, Children's Mercy Hospital, Kansas City, Missouri, United States
,
Pablo Aguayo
1   Department of Surgery, Children's Mercy Hospital, Kansas City, Missouri, United States
,
Jason D. Fraser
1   Department of Surgery, Children's Mercy Hospital, Kansas City, Missouri, United States
,
George W. Holcomb III
1   Department of Surgery, Children's Mercy Hospital, Kansas City, Missouri, United States
› Author Affiliations
Further Information

Publication History

10 May 2016

24 June 2016

Publication Date:
14 August 2016 (online)

Abstract

Purpose Several surgeons have documented outcomes following the Nuss operation. Most reports have described the use of thoracoscopy to avoid cardiac injury. Since 1999, our group has utilized a subxiphoid incision, allowing insertion of the surgeon's finger into the substernal space to help guide the bar across the mediastinum. Our initial experience has been reported and we are now reporting our entire experience to date.

Methods A retrospective review was conducted on all patients who underwent pectus excavatum repair using a subxiphoid incision from December, 1999 to September, 2015.

Results During the study period, 554 repairs were performed. A total of 80% of the patients were male. The mean age was 14.3 years ± 3.1, the mean operating time was 52 minutes ± 17.4, the mean length of stay was 4.2 days ± 1.1, and the mean time to bar removal was 2.7 years ± 0.7. A total of 20 patients (3.6%) received two bars. No patients sustained cardiac injury or evidence of pericarditis. Postoperatively, 22 patients (4%) developed an infection, either cellulitis or a local abscess requiring incision and drainage and/or antibiotics. In four of these 22 patients, the wound infection developed after the bar had been removed. Only one patient required bar removal before 2 years due to an infection. A total of 12 patients required either repositioning of the bar due to rotation (4) or removal of a stabilizer due to chronic discomfort (8), 2 required early bar removal for chronic pain, and 1 patient developed a tension pneumothorax in the operating room. A recurrence has developed in two patients but neither patient has desired correction.

Conclusion In this relatively large series of patients, the addition of a subxiphoid incision to the technique has allowed for safe passage of the bar across the mediastinum to avoid cardiac injury during the Nuss operation.

 
  • References

  • 1 Kelly RE, Goretsky MJ, Obermeyer R , et al. Twenty-one years of experience with minimally invasive repair of pectus excavatum by the Nuss procedure in 1215 patients. Ann Surg 2010; 252 (6) 1072-1081
  • 2 Hanna WC, Ko MA, Blitz M, Shargall Y, Compeau CG. Thoracoscopic Nuss procedure for young adults with pectus excavatum: excellent midterm results and patient satisfaction. Ann Thorac Surg 2013; 96 (3) 1033-1036 , discussion 1037–1038
  • 3 Shu Q, Shi Z, Xu WZ , et al. Experience in minimally invasive Nuss operation for 406 children with pectus excavatum. World J Pediatr 2011; 7 (3) 257-261
  • 4 Clark JJ, Johnson SM. Single incision Nuss procedure for pectus excavatum. Pediatr Surg Int 2011; 27 (7) 733-736
  • 5 Ohno K, Nakamura T, Azuma T, Yamada H, Hayashi H, Masahata K. Modification of the Nuss procedure for pectus excavatum to prevent cardiac perforation. J Pediatr Surg 2009; 44 (12) 2426-2430
  • 6 Liu SL, Li L, Cheng W , et al. Total extrapleura sternal elevation for the correction of pectus excavatum in children. J Laparoendosc Adv Surg Tech A 2009; 19 (Suppl. 01) S223-S225
  • 7 Cheng YL, Lee SC, Huang TW, Wu CT. Efficacy and safety of modified bilateral thoracoscopy-assisted Nuss procedure in adult patients with pectus excavatum. Eur J Cardiothorac Surg 2008; 34 (5) 1057-1061
  • 8 Furukawa H, Sasaki S, William M , et al. Modification of thoracoscopy in pectus excavatum: insertion of both thoracoscope and introducer through a single incision to maximise visualisation. Scand J Plast Reconstr Surg Hand Surg 2007; 41 (4) 189-192
  • 9 Palmer B, Yedlin S, Kim S. Decreased risk of complications with bilateral thoracoscopy and left-to-right mediastinal dissection during minimally invasive repair of pectus excavatum. Eur J Pediatr Surg 2007; 17 (2) 81-83
  • 10 Schaarschmidt K, Kolberg-Schwerdt A, Lempe M, Schlesinger F, Bunke K, Strauss J. Extrapleural, submuscular bars placed by bilateral thoracoscopy—a new improvement in modified Nuss funnel chest repair. J Pediatr Surg 2005; 40 (9) 1407-1410
  • 11 St Peter SD, Sharp SW, Ostlie DJ, Snyder CL, Holcomb III GW, Sharp RJ. Use of a subxiphoid incision for pectus bar placement in the repair of pectus excavatum. J Pediatr Surg 2010; 45 (6) 1361-1364
  • 12 Park CH, Kim TH, Haam SJ, Lee S. Rib overgrowth may be a contributing factor for pectus excavatum: Evaluation of prepubertal patients younger than 10years old. J Pediatr Surg 2015; 50 (11) 1945-1948
  • 13 Ravitch MM. The operative treatment of pectus excavatum. Ann Surg 1949; 129 (4) 429-444
  • 14 Nuss D, Kelly Jr RE, Croitoru DP, Katz ME. A 10-year review of a minimally invasive technique for the correction of pectus excavatum. J Pediatr Surg 1998; 33 (4) 545-552
  • 15 Bouchard S, Hong AR, Gilchrist BF, Kuenzler KA. Catastrophic cardiac injuries encountered during the minimally invasive repair of pectus excavatum. Semin Pediatr Surg 2009; 18 (2) 66-72
  • 16 Barsness K, Bruny J, Janik JS, Partrick DA. Delayed near-fatal hemorrhage after Nuss bar displacement. J Pediatr Surg 2005; 40 (11) e5-e6
  • 17 Hoel TN, Rein KA, Svennevig JL. A life-threatening complication of the Nuss procedure for pectus excavatum. Ann Thorac Surg 2006; 81 (1) 370-372
  • 18 Becmeur F, Ferreira CG, Haecker FM, Schneider A, Lacreuse I. Pectus excavatum repair according to Nuss: is it safe to place a retrosternal bar by a transpleural approach, under thoracoscopic vision?. J Laparoendosc Adv Surg Tech A 2011; 21 (8) 757-761
  • 19 Notrica DM, McMahon LE, Johnson KN, Velez DA, McGill LC, Jaroszewski DE. Life-threatening hemorrhage during removal of a Nuss bar associated with sternal erosion. Ann Thorac Surg 2014; 98 (3) 1104-1106
  • 20 Hendrickson RJ, Bensard DD, Janik JS, Partrick DA. Efficacy of left thoracoscopy and blunt mediastinal dissection during the Nuss procedure for pectus excavatum. J Pediatr Surg 2005; 40 (8) 1312-1314
  • 21 Saxena AK, Castellani C, Höllwarth ME. Surgical aspects of thoracoscopy and efficacy of right thoracoscopy in minimally invasive repair of pectus excavatum. J Thorac Cardiovasc Surg 2007; 133 (5) 1201-1205
  • 22 Sacco-Casamassima MG, Goldstein SD, Gause CD , et al. Minimally invasive repair of pectus excavatum: analyzing contemporary practice in 50 ACS NSQIP-pediatric institutions. Pediatr Surg Int 2015; 31 (5) 493-499
  • 23 Sacco Casamassima MG, Goldstein SD, Salazar JH, McIltrot KH, Abdullah F, Colombani PM. Perioperative strategies and technical modifications to the Nuss repair for pectus excavatum in pediatric patients: a large volume, single institution experience. J Pediatr Surg 2014; 49 (4) 575-582
  • 24 Obermeyer RJ, Godbout E, Goretsky MJ , et al. Risk factors and management of Nuss bar infections in 1717 patients over 25 years. J Pediatr Surg 2016; 51 (1) 154-158
  • 25 Shin S, Goretsky MJ, Kelly Jr RE, Gustin T, Nuss D. Infectious complications after the Nuss repair in a series of 863 patients. J Pediatr Surg 2007; 42 (1) 87-92
  • 26 Shu Q, Shi Z, Xu W-Z , et al. Experience in minimally invasive Nuss operation for 406 children with pectus excavatum. World J Pediatr 2011; 7 (3) 257-261
  • 27 Ortega G, Rhee DS, Papandria DJ , et al. An evaluation of surgical site infections by wound classification system using the ACS-NSQIP. J Surg Res 2012; 174 (1) 33-38
  • 28 Tanaka K, Kuwashima N, Ashizuka S, Yoshizawa J, Ohki T. Risk factors of infection of implanted device after the Nuss procedure. Pediatr Surg Int 2012; 28 (9) 873-876