Subscribe to RSS
DOI: 10.1055/a-2249-0056
A Novel Technique of Aseptic Manufacture of Autologous Serum Eye Drops (ASEDs) and Sterility Analysis of the Bottled Ophtioles
Ein neuartiges Verfahren zur aseptischen Herstellung von autologen Serum-Augentropfen (ASED) und Sterilitätsanalyse der abgefüllten Ophtiolen
Abstract
Purpose To introduce a novel technique of the aseptic manufacture of autologous serum eye drops (ASEDs) with a prefiltered closed system and to analyze the sterility of the produced ophtioles between 2018 and 2022.
Methods This is a prospective single-center study conducted at the Department of Ophthalmology at a Swiss University Hospital between 2018 and 2022. For regulatory reasons, closed systems for manufacturing ASEDs are strongly recommended. We attached an upstream sterile filter (Sterivex PES0.22 µm Burlington, USA) to a commercially available closed system (COL System Modena, Italy) for manufacturing ASEDs. The goal of this novel approach was to reduce the microbiological contamination of the donated autologous blood. Using the presented manufacturing method, we are able to produce, on average, 56 ophtioles per batch, containing either 1.45 mL or 2.5 mL of autologous serum per ophtiole. For each batch of ASEDs, we performed a microbiological analysis by automated blood culture testing (BACTEC). This system examines the presence of bacteria and fungi.
Results We analyzed all manufactured batches between 2018 and 2022. None of the 2297 batches and the resulting 129 060 ophtioles showed bacterial or mycotic contamination. During the analyzed period, two batches were discarded: one due to fibrin-lipid aggregations, further microbiological and histological work-up excluded any contamination; another due to false-positive HIV in serological testing. Overall, the contamination rate was 0%, and the batch discharge rate was 0.09%.
Conclusions The combination of upstream sterile filtration with a commercial closed system for manufacturing ASEDs proved to be effective in ensuring sterility without any contamination over the past 4 years. This is becoming crucial, as the demand for autologous blood products for treating ocular surface disorders, such as refractory dry eyes or nonhealing defects of the corneal epithelium, is on the rise.
Zusammenfassung
Hintergrund Einführung einer neuen Technik zur aseptischen Herstellung von autologen Serum-Augentropfen (ASED) mit einem vorgefilterten geschlossenen System und Analyse der Sterilität der hergestellten Ophtiolen zwischen 2018 und 2022.
Methoden Es handelt sich um eine prospektive Single-Center-Studie, die an der Abteilung für Augenheilkunde eines Schweizer Universitätsspitals zwischen 2018 und 2022 durchgeführt wurde. Aus regulatorischen Gründen werden geschlossene Systeme zur Herstellung von ASED dringend empfohlen. Wir haben einen vorgeschalteten Sterilfilter (Sterivex PES0,22 µm) an ein handelsübliches geschlossenes System (COL-System) zur Herstellung von ASED angeschlossen. Ziel dieses neuartigen Ansatzes war es, die mikrobiologische Kontamination des gespendeten Eigenblutes zu reduzieren. Mit dem vorgestellten Herstellungsverfahren sind wir in der Lage, durchschnittlich 56 Ophtiolen pro Charge herzustellen, die entweder 1,45 mL oder 2,5 mL autologes Serum pro Ophtiole enthalten. Für jede Charge von ASED wurde eine mikrobiologische Analyse mittels automatischer Blutkulturtests (BACTEC) durchgeführt. Mit diesem System wird das Vorhandensein von Bakterien und Pilzen untersucht.
Ergebnisse Wir analysierten alle zwischen 2018 und 2022 hergestellten Chargen. Keine der 2297 Chargen und der daraus resultierenden 129 060 Ophtiolen wies eine bakterielle oder mykotische Kontamination auf. Während des analysierten Zeitraums wurden 2 Chargen verworfen: Eine aufgrund von Fibrin-Lipid-Aggregationen und eine weitere wegen eines falsch positiven HIV-Tests bei der serologischen Untersuchung. Insgesamt lag die Kontaminationsrate bei 0% und die Chargenausscheidungsrate bei 0,09%.
Schlussfolgerungen Die Kombination aus vorgeschalteter Sterilfiltration und einem kommerziellen geschlossenen System zur Herstellung von ASED hat sich in den letzten 4 Jahren als wirksam erwiesen, um die Sterilität ohne jegliche Kontamination zu gewährleisten. Dies ist von entscheidender Bedeutung, da die Nachfrage nach Eigenblutprodukten zur Behandlung von Augenoberflächenerkrankungen wie therapierefraktärem trockenem Auge oder nicht heilenden Hornhautepitheldefekten zunimmt.
Schlüsselwörter
autologe Serumaugentropfen - Ophtiolen - Sterilität - Kontamination - geschlossenes SystemPublication History
Received: 29 October 2023
Accepted: 03 January 2024
Article published online:
23 April 2024
© 2024. Thieme. All rights reserved.
Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany
-
References
- 1 Fox RI, Chan R, Michelson JB. et al. Beneficial effect of artificial tears made with autologous serum in patients with keratoconjunctivitis sicca. Arthritis Rheum 1984; 27: 459-461
- 2 Kim KM, Shin YT, Kim HK. Effect of autologous platelet-rich plasma on persistent corneal epithelial defect after infectious keratitis. Jpn J Ophthalmol 2012; 56: 544-550
- 3 Hussain M, Shtein RM, Sugar A. et al. Long-term use of autologous serum 50 % eye drops for the treatment of dry eye disease. Cornea 2014; 33: 1245-1251
- 4 Lekhanont K, Jongkhajornpong P, Choubtum L. et al. Topical 100 % serum eye drops for treating corneal epithelial defect after ocular surgery. Biomed Res Int 2013; 2013: 521315
- 5 Tappeiner C, Heiligenhaus A, Halter JP. et al. Challenges and concepts in the diagnosis and management of ocular graft-versus-host disease. Front Med (Lausanne) 2023; 10: 1133381
- 6 Metheetrairut C, Ngowyutagon P, Tunganuntarat A. et al. Comparison of epitheliotrophic factors in platelet-rich plasma versus autologous serum and their treatment efficacy in dry eye disease. Sci Rep 2022; 12: 8906
- 7 Shtein RM, Shen JF, Kuo AN. et al. Autologous Serum-Based Eye Drops for Treatment of Ocular Surface Disease: A Report by the American Academy of Ophthalmology. Ophthalmology 2020; 127: 128-133
- 8 Hotta F, Eguchi H, Kuwahara T. et al. Disturbances in the ocular surface microbiome by perioperative antimicrobial eye drops. Front Cell Infect Microbiol 2023; 13: 1172345
- 9 Yang Y, Zhu X, Yang J. et al. An Environmental Control Experiment for Contamination of the Production and Storage of 20 % Autologous Serum Eye Drops. Curr Eye Res 2020; 45: 1364-1368
- 10 Thanathanee O, Phanphruk W, Anutarapongpan O. et al. Contamination risk of 100 % autologous serum eye drops in management of ocular surface diseases. Cornea 2013; 32: 1116-1119
- 11 Bell M, Bogar C, Plante J. et al. Effectiveness of a Novel Specimen Collection System in Reducing Blood Culture Contamination Rates. J Emerg Nurs 2018; 44: 570-575
- 12 Maeda N, Mori N, Shinjoh M. et al. Comparison of 0.5 % chlorhexidine gluconate alcohol with 10 % povidone-iodine for skin disinfection in children to prevent blood culture contamination. J Infect Chemother 2021; 27: 1027-1032
- 13 Moonsuk B, Hae IK, Joung HP. et al. Improvement of blood culture contamination rate, blood volume, and true positive rate after introducing a dedicated phlebotomy team. Eur J Clin Microbiol Infect Dis 2019; 38: 325-330
- 14 Giancarlo ML, Liviana C, Vanessa P. et al. Reduction of the risk of bacterial contamination of blood components through diversion of the first part of the donation of blood and blood components. Blood Transfus 2009; 7: 86-93
- 15 Swissmedic. Merkblatt über nichtstandardisierbare Arzneimittel und zur Liste von nichtstandardisierbaren Arzneimitteln und Arzneimittelgruppen mit zulassungspflichtigem Herstellungsverfahren nach Anhang 3 VAZV. Stand: 18. Mai 2022. Accessed January 24, 2024 at: https://www.swissmedic.ch/dam/swissmedic/de/dokumente/bewilligungen/transplantate/mb_nichtstandardisierbare_am_und_liste.pdf.download.pdf/Merkblatt_lun_jd_scg_DE.pdf
- 16 European Directorate for the Quality of Medicines & HealthCare of the Council of Europe (EDQM). Guide to the quality and safety of tissues and cells for human application. 5th ed., 15 December 2022. Accessed January 24, 2024 at: https://www.edqm.eu/en/guide-to-the-quality-and-safety-of-tissues-and-cells-for-human-application1
- 17 Bradley JC, Simoni J, Bradley RH. et al. Time- and temperature-dependent stability of growth factor peptides in human autologous serum eye drops. Cornea 2009; 28: 200-205
- 18 Geerling G, Hartwig D. Autologous serum eyedrops for ocular surface disorders. Cornea Ext Eye Dis 2006; 20: 120
- 19 Sanak F, Baenninger P, Kaufmann C. et al. The Lucerne Protocol for the Production of Autologous Serum Eyedrops. Klin Monbl Augenheilkd 2021; 238: 346-348
- 20 Deguchi Y, Hori Y, Kaga A. et al. Evaluation of Adsorption onto Syringe Filters Used to Prepare Autologous Serum Eye Drops. ARVO Annual Meeting Abstract. Invest Ophthalmol Vis Sci 2012; 53: 585