Subscribe to RSS
DOI: 10.1055/a-2662-8526
Line Insertion through a Long Umbilical Stump: A Concept Generating Laboratory Study
Funding None.

Abstract
Objective
Umbilical line insertion involves discomfort for preterm infants. We hypothesized that a 10- to 20-cm umbilical cord segment can be catheterized with an appropriate guide wire. This may facilitate line establishment with minimal baby discomfort.
Study Design
A laboratory proof-of-concept study, performed on umbilical cord segments removed from babies after delivery. In phase 1, we used a variety of techniques to determine an ideal method for long-segment umbilical vein catheterization. In phase 2, we documented the rate of successful catheter advancement using this method.
Results
We successfully advanced the catheter from the insertion point to the proximal end of the cord, an average distance of 15.7 ± 3.5 cm, in 7 out of 10 cords.
Conclusion
It is possible to advance a catheter within the umbilical vein through a long umbilical cord segment. Clinical studies are required to evaluate whether this method may facilitate minimal handling insertion of umbilical catheters.
Key Points
-
This is an umbilical vein cannulation proof-of-concept laboratory study.
-
A line can be advanced 10 to 20 cm in an umbilical cord.
-
The proposed technique may support a minimal handling approach.
-
Further clinical studies are required.
Keywords
umbilical line - umbilical cord - newborns - preterm infant - minimal handling - Seldinger technique* These authors contributed equally to the study.
Publication History
Received: 28 January 2025
Accepted: 22 July 2025
Article published online:
04 August 2025
© 2025. Thieme. All rights reserved.
Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA
-
References
- 1 Safer Care Victoria. Catheter complications. Accessed June 6, 2024 at: https://www.safercare.vic.gov.au/best-practice-improvement/clinical-guidance/neonatal/umbilical-vein-catheterisation-for-neonates#goto-cathetercomplications
- 2 Yu YH, Wang L, Huang L. et al. Association between admission hypothermia and outcomes in very low birth weight infants in China: a multicentre prospective study. BMC Pediatr 2020; 20 (01) 321
- 3 Kramer KP, Minot K, Butler C. et al. Reduction of severe intraventricular hemorrhage in preterm infants: A quality improvement project. Pediatrics 2022; 149 (03) e2021050652
- 4 Selvanathan T, Ufkes S, Guo T. et al. Pain exposure and brain connectivity in preterm infants. JAMA Netw Open 2024; 7 (03) e242551
- 5 Kozyak BW, Fraga MV, Juliano CE. et al. Real-time ultrasound guidance for umbilical venous cannulation in neonates with congenital heart disease. Pediatr Crit Care Med 2022; 23 (05) e257-e266
- 6 Duerden EG, Grunau RE, Chau V. et al. Association of early skin breaks and neonatal thalamic maturation: A modifiable risk?. Neurology 2020; 95 (24) e3420-e3427
- 7 Torres Del Pino M, Gómez Santos E, Domínguez Quintero ML. et al. Steps to improve umbilical vein catheterization in neonatal care. An Pediatr (Engl Ed) 2023; 99 (03) 155-161
- 8 Schwaberger B, Schlatzer C, Freidorfer D. et al. The use of a disposable umbilical clamp to secure an umbilical venous catheter in neonatal emergencies-an experimental feasibility study. Children (Basel) 2021; 8 (12) 1093
- 9 Lockwood J, Desai N. Central venous access. Br J Hosp Med (Lond) 2019; 80 (08) C114-C119