J Hand Microsurg 2015; 07(01): 25-29
DOI: 10.1007/s12593-014-0156-0
Original Article
Thieme Medical and Scientific Publishers Private Ltd.

Clinical Results of Flexor Tendon Repair in Zone II Using a six Strand Double Loop Technique

Christiana Savvidou
,
Tsu-Min Tsai

Verantwortlicher Herausgeber dieser Rubrik:
Weitere Informationen

Publikationsverlauf

11. April 2014

18. August 2014

Publikationsdatum:
13. September 2016 (online)

Preview

Abstract

The purpose of this study is to report the clinical results after repair of flexor tendon zone II injuries utilizing a 6-strand double-loop technique and early post-operative active rehabilitation. We retrospectively reviewed 22 patients involving 51 cases with zone II flexor tendon repair using a six strand double loop technique from September 1996 to December 2012. Most common mechanism of injuries was sharp lacerations (86.5 %). Tendon injuries occurred equally in manual and non-manual workers and were work-related in 33 % of the cases. The Strickland score for active range of motion (ROM) postoperatively was excellent and good in the majority of the cases (81 %). The rupture rate was 1.9 %. The six strand double loop technique for Zone II flexor tendon repair leads to good and excellent motion in the majority of patients and low re- rupture rate. It is clinically effective and allows for early postoperative active rehabilitation.