Detection Methods for Profiling and Quantification
HPLC-UV (ultraviolet detection)
Among all HPLC detectors, the most simple and the most widely used is UV [8]. Although it suffers from some limitations, particularly for NPs that do not possess
UV chromophores, it has the best combination of sensitivity, linearity, versatility,
and reliability of all the LC detectors developed so far. Most NPs absorb UV light
in the range of 200 – 550 nm, including all substances having one or more double bonds
and all substances that have unshared electrons. Thus, even compounds having weak
chromophores, such as triterpene glycosides, can be successfully detected by UV at
short wavelengths (203 nm) [9]. In this case, however, several mobile-phase constituents that exhibit high UV cut-offs
should be avoided because they might blind the detection of NPs with weak chromophores
[10].
In UV detection, the relationship between the intensity of light transmitted through
the detector cell and the solute concentration is given by Beer’s Law [11]. The two factors that control the detector sensitivity are the magnitude of the
extinction coefficient of the analyte of interest at a given wavelength and the path
length of the light passing through the UV cell. The sensitivity will increase with
increasing path length, but a compromise must be found with the cell volume in order
to avoid peak dispersion [8].
Three types of UV detectors are available: fixed wavelength, multiple wavelength,
or photodiode array (DAD). The fixed-wavelength detector is the least expensive and
has higher intrinsic sensitivity because the light is emitted at specific wavelengths
with given lamps. However, the multiple-wavelength detector is more versatile and
can often compensate for its lower sensitivity when a wavelength with the highest
extinction coefficient for the solutes of interest is chosen. The photodiode array
will be treated in the hyphenation section, as it can provide complete UV spectra
of the constituent during separation. Limits of detection (LODs) can reach 10 – 8 g/mL, with a linear dynamic range of about three orders of magnitude.
Often, the separation of crude extracts requires a gradient elution which cause a
shift of the baseline at low wavelengths that can be avoided when working with modifiers
having low UV cut-offs such as phosphate buffers or trifluoroacetic acid (TFA). These
modifiers, however, are not optimal in multi-hyphenated systems with HPLC-MS (not
volatile, ion suppression) and should be avoided [12].
Many publications refer to the application of HPLC-UV at a single wavelength for the
detection of nearly all NPs having a chromophore for both profiling and quantification
purposes. An exhaustive survey would exceed the frame of this paper. Many applications
for flavonoids, terpenes, alkaloids, coumarins, alkamides, and polyacetylene have
been summarised in a review [13]. Some selected quantitative methods are discussed here.
Being simple and inexpensive, HPLC-UV is used in several pharmacopoeias for the quantification
of individual NPs in the quality control of herbal drugs or phytopreparations. In
the U.S. and European pharmacopoeias [14], [15], HPLC-UV (203 nm) methods are used for the determination of the total ginsenoside
content of Ginseng roots and the measurement of the ratio of the ginsenosides, Rg1 and Rb1 [16]. This analysis is indeed important to assess pharmacological effects, as a low Rg1/Rb1
ratio is linked to the calming properties of American ginseng, while the high Rg1/Rb1
ratio could be the reason for the stimulating characteristics of Asian ginseng. HPLC-UV
also has been used for the quantification of flavonoid, naphthodianthrone, and phloroglucinol
constituents of Hypericum perforatum. The developed method used a ternary solvent system in the gradient mode (50 min)
and enabled a baseline separation of 16 main constituents, which were quantified based
on their relative response factors at 270 nm and compared with rutin as an external
standard [17]. A more rapid method (5 min) using fast-gradient elution for a specific determination
of naphthodianthrones (590 nm) and phloroglucinols (270 nm) also has been reported
[18]. Many papers refer to the HPLC-UV analysis of another important herbal drug, Ginkgo biloba. A complete profiling of most of the flavonoids (350 nm) (33 compounds detected by
comparison with standards) was reported by Hasler et al. [19]. The same authors also proposed an HPLC-UV method, which includes the hydrolysis
of all glycosides and the subsequent quantification of three main flavonoid aglycones
(quercetin, kaempferol, and isorhamnetin) for the determination of the total flavonoid
content. Recently, another HPLC-UV method (350 nm) has been reported, which includes
the quantification of two glycosides (rutin and quercitrin) as markers, in addition
to the three aglycones [20]. An analysis of 10 commercial samples revealed that problems of adulteration with
rutin exist to fulfil the total flavonoid requirement (24 %), and thus in-depth quality
control needs complete profiling [21]. Recently a multivariate data analysis (MVDA) of Ginkgo products was performed based on their HPLC-UV profiles, and the results were compared
with the traditional flavonol quantification method [22]. This analysis revealed that there are significant variations in the relative concentrations
of individual flavonols in commercial products. The other active ingredients in Ginkgo are the terpene trilactones, which are standardised at 6 % in the extracts. These
terpenes exhibit rather weak chromophores (λ 220 nm) and are difficult to detect in the presence of the strongly UV-absorbing
flavonoids [23]. They have thus successfully been quantified by other methods such as ELSD [24] (see below). In Gingko, the level of highly allergenic alkylphenols (ginkgolic acids, cardanols, and cardols)
also needs to be assessed, and a limit of 5 ppm has been proposed in the EU and U.S. pharmacopoeias.
An in-depth analysis requires GC-MS [25] or HPLC-MS [26], but their total amount can be determined by a simple HPLC-UV (210 nm) analysis
without enrichment procedures after peak purity assessment by HPLC-DAD-MS [27].
In other cases, for the same plant extract, quantification may require both HPLC-UV
and HPLC-MS. This was necessary for the standardisation of the constituents of woad
(Isatis tinctoria). In this case, when possible, HPLC-UV was preferred to HPLC-MS because of the lower
RSD obtained [28].
Recently, other simple HPLC-UV methods for the standardisation of new herbal supplements
coming on the market such as Pueraria lobata, also known as Kudzu (Japan), have been developed. In this case, a fully validated
method following the ICH guidelines for the quantification of the isoflavone content
of this plant has been reported [29]. Similarly a method for profiling coumarins in different Angelica species has also been validated [30].
HPLC-UV methods also can be used to compare the fingerprint profiles of closely related
species or the same species from different locations. This was the case for Herba
Oldenlandiae, a plant of the Chinese pharmacopoeia, which can be adulterated by different
Oldenlandia species. A comparative analysis of chemical components was obtained by software calculation
of correlation coefficients of the entire UV chromatograms for appraising similarity
[31]. Fingerprint-based similarity also can be employed for chemotaxonomic study by applying
hierarchical clustering analysis (HCA) and principal component analysis (PCA) to a
set of HPLC-UV profiles, as was performed for different Taxus species [32].
In [Fig. 1], the profiling of the constituents of the crude extract of the model plant Arabidopsis thaliana obtained with UV detection at two standard wavelengths (254 and 350 nm) is illustrated.
A selective detection of flavonoids (F) and sinapoyl derivatives (S) was performed
at 350 nm. Detection at 254 nm was less selective as more UV active constituents were
recorded; this included glucosinolates (G), which have UV maxima at 227 nm. However,
fewer peaks were recorded with UV than with MS or ELSD detection methods (see below).
In this example, the high chromatographic resolution was provided by ultra high-pressure
liquid chromatography (UHPLC) [5], which yielded very high peak capacities (see inset c in the MS trace) [33], [34].
Fig. 1 Comparison of different detection techniques used to monitor the UPLC separation of
the crude leaf extract of Arabidopsis thaliana. UPLC conditions: Column BEH C18 : 1.0 × 50 mm and 2.1 × 150 mm, 1.7 μm (Waters Acquity);
gradient 5 % to 98 % ACN (0.1 % formic acid) in 45 min; temperature 35 °C; flow rate
300 μL/min. ESI-TOF-MS detection: LCT Premier (Waters); capillary voltage 2800 V; cone
voltage 40 V; desolvation temperature 250 °C; desolvation gas flow 550 L/h; PI and
NI in the range m/z = 100 – 1000 with a scan time of 0.25 s. UV-DAD detection: 220 – 500 nm. DEDL detection:
SEDERE sedex85, P
neb = 3 bar, T
evap = 50 °C, gain 8. Compound F is a flavonol glycoside, G a glucosinolate, S a synapoyl
derivative, and L a galactolipid. Insets a and c: UV-DAD and TOF-MS spectra of F. Inset b: Zoom into the BPI-ESI NI chromatogram showing the important number of minor peaks
detected.
HPLC-FD (fluorescence detection)
Compared with HPLC-UV, fluorescence detection (FD) affords much greater sensitivity
and selectivity ([Table 1]). In fluorescence, the molecular absorption of a photon triggers the emission of
another photon with a longer wavelength. This difference in wavelengths (absorption
vs. emission) provides more selectivity, and the fluorescent light is measured against
a very low-light background, thus improving the S/N ratio. Unfortunately, relatively
few NPs fluoresce in a practical range of wavelengths. However, many substances can
be made to fluoresce by forming appropriate derivatives [8].
Compared with UV, FD has been scarcely used for the detection NPs. Most of the applications
are related to the very sensitive detection of aflatoxins in food because this class
of NPs contains natural fluorescence [35]. An FD method for the quantification of aflatoxins in herbs also has been recently
reported [36]. It combines sample cleanup with immunoaffinity columns followed by HPLC-FD, and
it enabled the detection of aflatoxin content ranging from 7 to 20 μg/kg in the plant
material. HPLC-FD also has been used for the screening of the major benzophenanthridine
alkaloids produced by cell cultures of Eschscholtzia californica [37]. Thanks to the selectivity of the method (excitation 330 nm, emission 570 nm), the
sample preparation was notably simplified compared with previous methods. The detection
of NPs that do not naturally fluoresce has been successfully achieved after the addition
of fluorescent tags. This was the case for the specific and sensitive detection of
the plant hormone jasmonic acid (LOD 3 ng/mL), which was tagged with the ADAM reagent
[38].
HPLC-CL (chemiluminescence)
Similar to fluorescence, chemiluminescence can be defined as the emission of light
from a molecule or atom in an electronically excited state produced by a chemical
reaction at an ordinary temperature without any associated generation of heat. Chemiluminescent
(CL) nitrogen detection is a relatively new technology for the detection of nitrogen-containing
molecules, including a broad range of pharmaceuticals with very high sensitivity up
to the femtogram range [39]. Because many compounds are not chemiluminescent, they can only be detected chemiluminescently
after being derivatised. The development of chemiluminogenic reagents has helped to
extend the application of CL detection, especially for pharmaceutical biomedical applications
[39]. In applications with HPLC, the reagents are applied post-column. For example, the
addition of potassium hexacyanoferrate(III) enables the detection of various carboxylic
acids in the form of N-(4-aminobutyl)-N-ethylisoluminol derivatives [40].
While being very sensitive, the method so far has been very scarcely applied to the
analysis of crude plant extracts. A study reported the sensitive HPLC-CL detection
of flavonoids (LOD 3 ng/mL) in phytopharmaceuticals containing Hippophae rhamnoides. The procedure was based on chemiluminescent enhancement by flavonols of the cerium(IV)-rhodamine
6G system in a sulphuric acid medium [41].
HPLC-ECD (electrochemical detection)
Many NPs have electroactive groups and are readily measurable and detectable by LC
with electrochemical detection (ECD). This detection method is inexpensive, sensitive,
selective, and widely accepted ([Table 1]) [10]. It is less selective than FD; however, NPs with electrochemical activity are common,
and the technique can be applied to a large number of analytes in either the oxidation
or reduction modes. Numerous functional groups are sensitive to oxidation, including
phenols, aromatics, amines, thiols, and quinolines, and many are compatible with reduction,
such as olefins, esters, ketones, aldehydes, ethers, and quinones.
ECD differs from other methods of detection because it alters the sample. Cells for
HPLC-ECD usually consist of three electrodes, the working, counter, and reference
electrodes, which can be aligned in several different geometries, although two main
designs exist. In coulometric systems, the eluent is directed through the electrode,
while in amperometric systems, the eluent passes over it. ECD detection is usually
performed by maintaining the potential of the working electrode at a fixed value relative
to the potential of the electrolyte, which is measured by the reference electrode.
The fixed potential difference applied between the working and the reference electrodes
drives the electrochemical reaction, and the resulting current is measured as a function
of the elution time. This allows for detection limits at the pmol level. The selectivity
of ECD depends on the accessible potential range, the number of compounds that are
active in this range, and the half-widths of the individual signals [10]. Pulsed techniques, which use multi-step potential-time waveforms to realise amperometric/coulometric
detection while maintaining uniform and reproducible electrode activity, are also
available for detection [42].
Modern interest in HPLC-ECD is stimulated by the recognition that electrochemistry
is ideal for the study of the metabolism of aromatic compounds. However, proper use
of LC-ECD requires knowledge of redox reactions and their dependence on mobile-phase
composition. In this respect, the study of electrode reaction mechanisms can sometimes
aid the elucidation of the mechanism of their interaction with living cells, such
as for antioxidant NPs [43]. The interest in the method resides also in the fact that the ECD can be easily
miniaturised and used in fully integrated chip-based systems.
HPLC-ECD is commonly used in many pharmaceutical, clinical, and biochemical laboratories
[10], [44]. Because antioxidants are electrochemically active, HPLC-ECD is well suited for
their accurate quantification. In this respect, the method has permitted the detection
and quantification of very low levels of antioxidants, such as carnosic acid in food
ingredients [45]. In plant extract profiling, coulometric electrode array detection has allowed for
the fingerprinting of 25 constituents (polyphenols and tanshinones) in Salvia miltiorrhiza after a careful selection of the optimal mobile-phase pH and working potentials [46]. The successful detection of various small phenolics, such as coumaric or ferulic
acids, with a gold polycrystalline electrode has been reported recently [47]. This method was also used for the quantification of the vanilloid content in Capsicum annuum extracts [48]. ECD was found to be more sensitive than UV for the normal-phase HPLC profiling
of diarylheptanoids in Alpinia officinarum (lesser galangal) [49]. Similarly, the simultaneous determination of hyperforin and total hypericin in
Hypericum perforatum was achieved after the photoconversion of the protoforms of hypericins in extracts
and tablets [50].
The antioxidant potential of polyphenols can be estimated by HPLC with coulometric
array detection because they are reducing agents, and their electrochemical responses
result from the donation of electrons. Some degree of correlation between the electrochemical
profiles of 17 flavonoids and 3 cinnamic acid derivatives and 3 different antioxidant
assays was established [52].
HPLC-ECD also has been used in many applications related to the analysis of drugs
in body fluids [44], [10]. Artemisinin, for example, was selectively detected and quantified in plasma using
a glassy carbon electrode by reductive ECD [52]. Similarly, acteoside was analysed by amperometric detection in rat blood and brain
microdialysate in a pharmacokinetic study [53]. Recently, different amino acid derivatives characteristic for Korean ginseng were
analysed by pulsed amperometric detection in both ginseng and plasma samples [54].
HPLC-RID (refractive index detection)
The detectors described previously are selective for analytes having specific spectroscopic
or physicochemical properties. In order to obtain a more universal response, other
detectors have been developed.
The first, most simple, and least expensive of these detectors is the refractive index
detector (RID), which was reported by Tiselius and Claesson [55] in 1942. It was indeed the first effective in-line LC detector. However, RID lacks
sensitivity, is very susceptible to changes in ambient temperature, pressure, and
flow rate, and cannot be used for gradient elution. Despite these disadvantages, this
detector has been useful for detecting compounds such as carbohydrates and polymers.
Recent applications in the NP field are very scarce, although this method was used
for the quantification of sugars in strawberry fruits [56]. HPLC-RID was also used to determine the sugar concentration in different dry extracts
of Hypericum perforatum after extensive SPE cleanup [57]. More recently, the terpene trilactones of Ginkgo biloba were successfully quantified by HPLC-RID after a very specific sample preparation
based on the ionisation of these terpenes (RSD < 3 %, LOD 0.1 μg, linear range 0.1 – 12
μg) [58].
Because of its inherent limitations, HPLC-RID has been favourably replaced by other
universal detection methods such as those described below.
HPLC-ELSD (evaporative light-scattering detection)
Evaporative light-scattering detection (ELSD) was introduced in 1966 by Ford and Kennard
[59]. ELSD is a quasi-universal detector for liquid chromatography, as it can detect
any analyte less volatile than the mobile phase, regardless of the optical, electrochemical,
or other analyte properties [60]. In this detector, the eluent is nebulised using a flow of nitrogen, and the resulting
aerosol is transported through a heated drift tube where the volatile components and
solvents are evaporated. The remaining solid fraction is subsequently introduced into
a detection cell where a light beam is directed onto the particles that will cause
scattering of the incident light detected by a photodiode or a photomultiplier. The
most important parameters affecting the ELSD signal response are the nebuliser gas
flow rate and the drift tube temperature [61]. The gas flow rate influences the droplet size of the column effluent before evaporation
occurs. Higher flow rates result in the formation of smaller aerosol droplets and
less scattering of light, with subsequent lower sensitivity, but they allow for a
more stable baseline. The drift tube temperature facilitates the evaporation of the
nebulised aerosol so that the light-scattering response of the non-volatile solute
can exclusively be determined. Higher temperatures are needed for the mobile phase
of high-aqueous-content or non-volatile solutes versus semi-volatile ones. However, the new generation of ELSD is able to vaporise the eluent
at low temperature, facilitating the detection of semi-volatile analytes. It is pertinent
to optimise these parameters to ensure that the optimal signal to noise ratio (S/N)
is achieved [62]. ELSD is a mass-dependent detector, in contrast to UV, which is a concentration-dependent
detector, and the generated response does not depend on the spectral or physicochemical
properties of the analyte. In theory, this means that ELSD generates a similar response
for equal amounts of mass present and thus a universal response factor. However, the
ELSD response also depends on the volatility of the compound and the mobile-phase
composition (in the case of gradient elution), which makes such quantification procedures
experimentally inaccessible. Thus, this interplay of several factors leads to a non-linear
response, which is one disadvantage of this type of detector and ultimately renders
direct linear regression for making calibration curves inaccurate [63]. In order to avoid the variation generated by the gradient elution, the post-column
addition of mobile-phase flow having an opposite composition is an interesting alternative
[64].
The increased interest in ELSD as a universal detector is that it is more compatible
with gradient elution than RID, and it is much less costly and easier to maintain
than an HPLC-MS platform (see below). However, it is used mostly as an additional
detector rather than a substitute. Recent papers have discussed advantages and potentialities
as well as several limitations of the method for both NP and pharmaceutical applications
[60], [63], [65].
In applications related to NPs, ESLD has been used mainly for the detection of compounds
with weak chromophores such as terpenes, in both aglycone [62] and glycosidic forms [66], saponins [67], and some alkaloids [68]. The method also has been applied in complement to HPLC-MS for surveying NP libraries
[69]. In this case, a wide range of products, including UV-active phenolics, were screened,
and an ELSD signal was obtained for all compounds (>100 ng injected). ELSD has been
used for the quantitative determination of the relevant active principles of herbal
drugs. A recent method for the detection of 14 ginsenosides in Korean red ginseng,
using digoxin as an internal standard, has been validated and applied to several ginseng
products [67]. All calibration curves showed good linearity using a log-log transformation (R
2 > 0.9833), and LODs of 0.075 – 0.30 μg and LOQs of 0.125 – 0.80 μg were achieved.
Thus, ELSD represents an interesting simple alternative to the UV detection method
(203 nm) of the pharmacopoeia. However, both UV and ELSD detections are often necessary
for profiling extracts, as was shown for the simultaneous determination of triterpenoids
(ELSD) and phytoecdysones (UV) in roots of Achyranthes bidentata (Amaranthaceae) [70].
The weakly UV-active ginkgolide and bilobalide of Ginkgo were also efficiently quantified by ELSD [71], [62] Camponovo et al. [71] noticed a specific response of ELSD for terpene trilactones versus flavonoids when
UV detection (220 nm) and ELSD detection were compared. Dubber et al. [62] were able to obtain a baseline separation of these compounds within 14 min, and
they have analysed several Ginkgo biloba products with LOQs of ca. 60 ng. Inter-day percentage standard deviations were all
better than 6 %. ELSD thus represents an interesting alternative to the GC dosage
usually performed for the standardisation of the terpene content of Ginkgo [72].
In the case of the crude extract profiling of Arabidopsis thaliana, shown in [Fig. 1], the ELSD response provided many more peaks than those detected in UV (254 and 350 nm),
especially for the detection of non-polar compounds (mainly lipids). Compounds detected
by ELSD in this leaf extract included the notably different galactolipids such as
(L), which were not visible in the UV traces.
HPLC-CAD (charged aerosol detection)
Charged aerosol detection (CAD) is a new technology for universal HPLC detection,
which derived from ELSD and was introduced by Dison and Peterson in 2002 [73]. The first steps of the operating principle of CAD are roughly comparable to that
of ELSD. Contrary to ELSD, however, with CAD, the dried particle stream is charged
with a corona discharge needle, and the resulting electrical charge is measured by
an electrometer [63]. The use of a corona discharge indicates some commonality with APCI-MS (see below);
however, CAD operates by detecting charge particles with a selected mobility range
rather than measuring individual gas-phase ions as in MS. Generally, CAD is more sensitive
than ELSD ([Table 1]), but this difference is strongly influenced by the LC modifier, as ELSD seems less
sensitive to increases in salt concentration [63]. This detection method provides a uniform response to non-volatile analytes independently
of their nature and a dynamic range up to 4 orders of magnitude [64].
For the detection of NPs with strong chromophores, UV usually performs better than
CAD or ELSD. However, these latter detection methods are more dedicated to the analysis
of non-UV-absorbing compounds, and of course their performances are in this case much
better [63].
Because it is a new detection method, CAD has not yet been used for NP detection in
crude extracts to our knowledge, although it has been used for a wide range of pharmaceutical
products. Both CAD and ELSD were evaluated for a library of more than 700 compounds
in the 150 to 700 Da range and failed only in the detection of two compounds having
small MWs [74]. It is noteworthy that successful quantitative analysis of triacylglycerols (TGs)
in plant oils has been achieved [75]. The method is advantageous in that no normalisation of the peak area is needed,
as is the case in HPLC-MS, where large differences in responses can occur.
HPLC-FID (flame ionisation detection)
While considering a universal detection method for HPLC, it is worth mentioning that
FID, which is a general detector for GC because it detects all carbon-containing molecules,
also has been applied to HPLC. However, in both normal- and reversed-phase modes,
the LC mobile phases contain organic molecules that will blind the FID [76]. Thus, HPLC-FID coupling implies working with 100 % water mobile phases. A major
problem is that water is a very weak mobile phase in RPLC at room temperature. However,
for selected compounds and with appropriate stationary phases, separations were realised
with pure water at ambient temperature [77]. Another alternative is to work with superheated water in the HTLC mode because,
when heated under pressure to temperatures between 80 °C and 250 °C, the polarity
of liquid water decreases markedly to the extent that it can replace the organic modifier
and act as the sole eluent [78].
While successful applications of HTLC-FID have been described [79] mainly for the separations alcohols, carbohydrates, and amino acids, the method
has been used very rarely.
HPLC-MS (mass spectrometry)
The application of HPLC-MS in the analysis and characterisation of natural products
has been recognised as a major breakthrough [80]. Indeed, while it is expensive, the use of a mass spectrometer as an HPLC detector
provides excellent sensitivity and selectivity for the analysis of NPs in complex
biological matrices. Furthermore, MS detection provides important structural information
online such as MW, molecular formula, and diagnostic fragments, which are crucial
for dereplication and rapid online characterisation of NPs (see below).
Historically, a main challenge in HPLC-MS was that high liquid flows from HPLC were
not compatible with the high vacuum required for the mass spectrometer. Since the
early 1980 s, a number of different interfaces have been developed to address this
issue and overcome these difficulties [81], [82]. One obvious way to prevent the harmful effects of the LC mobile phase for the mass
spectrometer was to remove the solvent prior to ionisation. This has led to the development
of moving belt interfaces for sample introduction into the low-pressure plasma sources.
The advantage of such devices was the possibility to generate electron impact (EI)
spectra, for example, for flavonoids [83], but they suffered from many other disadvantages and were abandoned. Another more
modern ”transport-type” interface in LC-MS is the particle beam [84], but it has scarcely been applied to natural products analysis. A new generation
of direct-EI interfaces coupled to nano-HPLC seems promising for generating such information-rich
types of spectra [85].
The overwhelming popularity of HPLC-MS today is largely due to atmospheric pressure
ionisation (API) interfaces including electrospray ionisation (ESI) and atmospheric
pressure chemical ionisation (APCI). For both ESI and APCI, ionisation occurs at atmospheric
pressure. Some combination of high voltage and heat is used to provide the ionisation
that is needed to produce the ions that are assayed by the MS system. In ESI, the
high-voltage field (3 – 5 kV) produces nebulisation of the column effluent resulting
in charged droplets that are directed toward the mass analyser. These droplets get
smaller as they approach the entrance to the mass analyser. As the droplets get smaller,
individual ions emerge in a process referred to as ”ion evaporation”; these ions are
then separated by the MS system. In APCI, heat is used to vaporise the column eluent,
and then a corona discharge is used to ionise solvent molecules, which then produce
the analyte ions via chemical ionisation mechanisms. More recently, a third type of
ionisation source, termed atmospheric pressure photoionisation (APPI), has become
available. In APPI, heat is used to vaporise the column eluent (similar to APCI),
but the ionisation is produced by way of an ultraviolet (UV) lamp that produces 10-eV
photons. Depending upon the solvent system used, the 10-eV photons will ionise either
the mobile-phase solvent or a dopant (e. g., toluene) added to the column effluent;
these ions then produce the analyte ions through various ionisation mechanisms including
charge or proton transfer [86].
These API methods generally provide a soft ionisation and mainly molecular ion species
in the form of either protonated molecules [M + H]+ (positive-ion mode, PI) or deprotonated molecules [M – H]− (negative-ion mode, NI). Different adducts (e. g., [M + Na]+ (PI) or [M + HCOO]− (NI)) are also produced, depending on the solutes and the modifiers used. It is important
to understand that analyte ionisation is largely compound dependant and is governed
mainly by proton affinity. As a rule of thumb for a good approximation, acidic molecules
(e. g., carboxylic acids or phenolics) will produce mainly [M – H]− in NI, while bases (e. g., alkaloids, amines) will generate [M + H]+ in PI. Compounds such as glycosides will have a high affinity for salts and will
tend to form sodium adducts in PI. Molecule fragmentation or partial declustering
of the adducts can be induced in one of the high-pressure regions of the ion beam
from the source to the mass analyser by collision-induced dissociation (CID) either
at the API source (in-source CID) or in conjunction with tandem MS (MS-MS) experiments
[82].
For HPLC--MS applications, many types of mass spectrometers can be used. Those that
are low resolution (LR), such as the single quadrupole (Q) mass spectrometers, are
the most commonly used and least expensive. Those giving high resolution (HR) and
exact mass capabilities, such as time-of-flight (TOF) instruments, are becoming increasingly
popular because they provide molecular formula information online and very precise
ion trace extraction (+/− 0.01 DA) for a specific detection. For measuring structurally
relevant fragments or for very specific detection, triple-quadrupole (QQQ) MS-MS systems
are the most commonly used. They are particularly useful for bioanalytical assays
and for specific quantification purposes in complex matrices through multiple reaction
monitoring (MRM) [87]. Ion-trap mass spectrometers have the unique capability of producing multiple-stage
MS-MS (MSn) data that may be essential for structural elucidation purposes. In addition to these
four kinds of mass spectrometers, there is a growing number of additional types, including
hybrid systems that combine LR and HR analysers for specific applications [86], [81].
Besides their widespread use for qualitative analysis [dereplication studies and crude
extract profiling (see below)], HPLC-MS and HPLC-MS-MS have been successfully used
for the specific detection and quantification of a large range of natural products.
While mainly simple quadrupole or triple-quadrupole analysers are considered for quantitative
studies, TOF instruments have recently increasingly been used as quantification tools,
even though historically they suffered from a narrow dynamic range [88].
A systematic HPLC-MS-ELSD study was conducted on 96 structurally diverse NPs, including
phenolics, alkaloids, amides, terpenoids, steroids, and polyketides, with a short
HPLC generic gradient (C18, 5 – 95 % ACN:H2O 0.1 % formic acid in 10 min). A good overall ionisation of most compounds with ESI
in both PI and NI mode was obtained [69]. The generic separation used was suitable for the elution of 86 of these 96 compounds
(RT > 1 min < 10 min); 75 were well detected in PI and 57 in NI, while all compounds
were detected by ELSD (4 μg on-column). A relatively universal detection can thus
be obtained if both PI mode and NI mode are used or alternated during acquisition
(see, for example, the profiling of A. thaliana constituents in [Fig. 1]). ESI (PI) is used mainly for alkaloids, APCI (PI) for pigments and carotenoids,
ESI (PI/NI) for triterpene glycosides, and APCI or ESI (PI/NI) for phenolics and flavonoids.
APCI is generally more suitable for non-polar constituents, while ESI provides a softer
ionisation and gives a good response for polar metabolites. On the other hand, APCI
is generally recognised to be less prone to matrix effects than ESI [89]. Only a few studies have referred to the use of APPI for NP detection [90]. An interesting work on the rapid analysis of stilbenes and derivatives from downy
mildew-infected grapevine has shown that APPI NI with acetone as doping reagent was
more sensitive than ESI and provided cleaner spectra [91]. Another study on anthocyanidins in wines has shown that both APPI and ESI-MS allow
the identification of a great number of these pigments. However, APPI ionisation was
found to be more specific towards the analyte, and the background noise was lower
[92]. In drug discovery, the performances of APPI, APCI, and ESI were evaluated on 106
standards and 241 proprietary drug candidates occupying a wide chemical space [93]. The results indicated that the detection rates in PI were 94 % for APPI, 84 % for
APCI, and 84 % for ESI. When PI and NI mode detection were combined, APPI detected
98 % of the compounds, while APCI and ESI each detected 91 %. In APPI, for analytes
of low polarity and low proton affinity, M+ was the predominant ion species generated, while for high-polarity and high-proton
affinity compounds, [M + H]+ ion species dominated the spectra. APPI is thus regarded by some authors [90] as a more universal detection method for HPLC-MS than APCI and ESI, but, at present,
it is still not widely used in natural products analysis.
Because ionisation is compound dependant in HPLC-MS, the choice of the interface,
the ion mode polarity, and the eluent composition might significantly affect the sensitivity.
The case of the analysis the triterpene glycosides of ginseng (ginsenosides) is treated
here to show how ionisation conditions were selected in different studies, as more
than 30 papers have dealt with their HPLC-MS detection in either plant extracts formulation
or body fluids. Indeed, while HPLC-UV [94], [95] and HPLC-ELSD [96] methods have been used for the detection of these saponins (see above), HPLC-MS
is the method of choice. The latter provides sensitive and selective detection in
shorter analysis time, as only isomers need to be separated and MS provides useful
structural information for a confirmation of the identity of these glycosides.
ESI (NI) was used for qualitative [97] and quantitative [98] studies mainly on various Panax spp. extracts. In conjunction with multiple-stage MS-MS (MSn) experiments, fragmentation of the [M – H]− provided the identification of 25 ginsenosides [97]. Another study demonstrated that different negative-ion source conditions were necessary
for an optimum ionisation of malonylated and non-malonylated ginsenosides [99]. Quantification of the ginsenosides Re, Rb1, and Rc in different dosage forms of
ginseng was provided by integration of their specific [M – H]− ion traces [98]. ESI (PI) was also used successfully for the detection and quantification of these
triterpene glycosides. Wang et al. reported a quantification method in MS-MS in the
single-reaction monitoring mode (SRM) for a very selective dosage of Rb1, Rc, and
Re [100]. In this case, both [M + Na]+ and [M + H]+ ions were observed, but the CID MS-MS spectra of the [M + H]+ species were found to be more informative than those of the sodiated adducts. ESI
(PI) was also used more recently in other quantification studies of Panax ginseng [101] and root and leaves of Panax quinquefolium [102], with an RSD of about 8 % in the latter case. With the same ionisation mode, a newly
developed UHPLC-QTOF-MS method has been efficiently used for the metabolite profiling
of different Panax species that were efficiently differentiated after PCA of the data [103]. Recently, APCI (PI and NI mode) was also investigated, and 30 ginsenosides were
determined. The NI mode provided [M – H]− ions, while in the PI mode, characteristic thermal degradation ions were recorded
[104]. Yu et al. also used APCI (NI) for the quantification of 6 ginsenosides as well
as other products in a complex traditional Chinese medicine (TCM) preparation (Naodesheng
injection) containing five plants, including Rhizoma Notoginseng [105]. In this case, the addition of 0.1 % formic acid into the mobile phase ensured the
formation of stable [M + HCOO]− molecular ions. The detection of these ions in the SIM mode produced data with acceptable
linearity, repeatability, precision and accuracy (LOQs 0.02 – 0.2 μg, linearity coefficient
> 0.9900, RSD < 3 %). It is also noteworthy to mention that ginsenosides have been
analysed and quantified in body fluids with similar HPLC-MS methods [106]. Thus, as shown here, depending on the conditions and the matrix studies, both APCI
and ESI (PI and NI) enable the quantification and identification of ginsenoside provided
that a correct optimisation is insured. Other types of saponins could also be well
detected by LC-MS. This was the case, for example, for the evaluation of the steroidal
saponin content of Rhizoma Paridis and Chinese multi-herb remedies that contain this
plant [107].
Another well-studied plant is Ginkgo biloba, for which both the terpene (ginkgolides and bilobalide) and the flavonoid contents
need to be quantified for standardisation purposes. Different HPLC-MS methods have
been used for the quantification of the terpenes because their detection in UV is
compromised by the strongly UV-absorbing flavonoids (see above). APCI (NI) enabled
a direct analysis of several Ginkgo preparations without pre-purification and provided LODs in the picogram range. Because
the detection relies on the specific extraction of the [M – H]−, a fast HPLC gradient was applied (14 min), which provided a high-throughput survey
of many samples [23]. More recently, ESI (NI) in MRM mode enabled an even more sensitive and specific
detection by the monitoring of specific MS-MS transitions of these terpenoids from
their precursor [M – H]− ions [108]. Ginkgolides have also been successfully analysed by APCI (NI) in MRM mode in plasma
samples for pharmacokinetic studies [109]. Another validated method for the specific detection of these compounds relies on
GC-MS [72]; in this case, however, a tedious sample preparation is needed.
Because of its high sensitivity and selectivity, HPLC-MS also represents a key technique
for the detection of toxic compounds present at trace levels. For example, HPLC-MS-MS
was evaluated for the quantification of urushiol congeners, which are responsible
for poison oak dermatitis. ESI (NI) in the MRM mode yielded LODs in the low ppm range
that are relevant for toxicological, clinical, and environmental studies of these
allergens [110]. Similarly, pyrrolizidine alkaloids, a class of hepatotoxic and tumorigenic phytochemicals,
have been analysed in honey samples and in extracts of Echium plantagineum. ESI (PI) provided good detection limits for these compounds; however, previous sample
enrichment with strong cation-exchange SPE was mandatory [110]. The consumption of slimming regimens made of Chinese herbal preparations has caused
intoxications associated with species of the Aristolochia genus, which contain highly nephrotoxic and carcinogenic metabolites called aristolochic
acids. Their detection in commercial dietary supplements was successfully achieved
in suspect preparations by using both UV and MS detection [112]. A recent LC-MS-MS method enabled the simultaneous detection of aristolochic acid
I and the marker compounds fanghinoline and tetrandrine in many TCM preparations [113].
In [Fig. 1], the type of detection provided by ESI in both NI and PI modes for the profiling
of Arabidopsis thaliana constituents is compared with the detection obtained by the UV and ELSD methods.
As shown, very complex MS base peak ion chromatograms (BPIs) were obtained in both
PI and NI mode. The number of constituents detected was higher than that observed
in UV and ELSD traces. It is noteworthy to observe that PI and NI modes do not generate
similar chromatograms and that some of the compounds were detected in only one of
the ionisation modes. This demonstrates that MS represents a rather universal detection
method of crude extract profiling if both PI and NI mode are used complementarily.
On the other hand, very specific detection can be obtained if the extracted chromatogram
of a given ion is displayed. For example, the ion trace m/z = 741.22 has been selected in [Fig. 1]. This ion corresponds to the protonated molecule of a flavonoid triglycoside F having
the molecular formula C33H41O19. Because TOF was used for detection in this example, a precise mass measurement was
obtained (741.2242 Da), and the corresponding ion chromatogram was extracted in a
narrow mass window of 0.01 Da. This enabled the very specific detection of this compound
among the other constituents, which would ensure its successful quantification.
As shown, HPLC-MS represents a very versatile HPLC detection method. Most of the API
interfaces available cover ionisation of the vast majority of NPs, provided that correct
conditions are used. Of course, the applications to NPs are manifold, and more details
can be found in dedicated reviews [80], [82], [114], [115]. Concerning the detection of NPs in biological fluids, an interesting review covers
the aspects related to sample preparation and quantification of flavonoids, alkaloids,
saponins, and sesquiterpenoids [116].
HPLC-NMR (nuclear magnetic resonance)
HPLC-NMR is used mainly for providing structural information online (see below), but,
as 1H-NMR can detect all analyte-bearing protons, HPLC-NMR also can be regarded as a universal
detection method [117]. However, it is not used for this purpose, mainly because of its lack of sensitivity
and the high costs associated with the use of this technique ([Table 1]). HPLC-19F-NMR has been used for the specific detection of fluorinated derivatives. This was
the case for studying the metabolic fate of 3-chloro-4-fluoroaniline in rat body fluids
[118].
Detection Methods for Online Structural Identification
Some of the spectroscopic methods used for the detection of NPs (DAD, MS, NMR, CD,
IR) also can be used in hyphenation with HPLC to generate structurally relevant data
for their online identification and dereplication purposes. When both chromatographic
and spectroscopic dimensions are used, the methods are referred to as ”LC-hyphenated
techniques.” Dereplication of NPs with these methods is strategic for guiding an efficient
lead-finding process [119]. However, this task is not easy to perform, because no exhaustive LC spectroscopic
databases are available. Furthermore, even if libraries of NP spectra could be efficiently
generated on a given LC-hyphenated system, their widespread use is complicated by
the fact that, contrary to GC-MS, most of the data, especially HPLC-MS and HPLC-MS-MS,
are instrument dependant [120]. Thus, for each new compound, both the order of the atoms and the stereochemical
orientations have to be elucidated de novo. Consequently, a single LC-hyphenated technique does not exist that is capable of
identifying online all secondary metabolites in a plant extract [121]. Ideally, hyphenated methods should provide the same quality of spectroscopic information
as that acquired from isolated pure products. However, this is not the case, and each
technique presents its limitations. The coupling of various hyphenated methods together
(hypernation) requires even more compromises to be made (compatibility of the eluent
composition, sensitivity and dynamic range of the methods being hypernated), but it
has the advantage that all structural information is obtained within one single analysis
[122].
For natural product analysis, the dereplication procedures rely mainly on HPLC-DAD-MS
[82] and chemotaxonomic information provided by NP databases [123]. When unknown natural products cannot be dereplicated by these means, complementary
information can be obtained by NMR either directly hyphenated with LC (HPLC-NMR) [124] or used at-line with preconcentration methods such as HPLC-SPE-NMR [125], [126] or after microfractionation with microflow HPLC-NMR methods such as CapNMR [119], or even with a combination of both techniques by CAP-SPE-NMR [127]. Other hyphenated methods, such as HPLC-IR [128] or HPLC-CD [129], can bring useful additional structural information.
The goal is not to cover HPLC hyphenation exhaustively here, as a dedicated review
on plant fingerprinting can be found in this issue. However, the methods will be discussed
briefly to complete the aspects regarding HPLC detection.
HPLC-DAD (photodiode array detection)
Photodiode array detection (DAD) [130] provides UV spectra directly online and is particularly useful for the detection
of natural products with characteristic chromophores [131]. For example, polyphenols can be efficiently localised by this method because they
possess characteristic chromophores. With this type of compound, DAD-UV spectral libraries
can be built and used for dereplication, but compounds have to be analysed under the
same HPLC conditions, as the composition of the mobile phase might affect the UV bands
slightly. Furthermore, the choice of modifiers affects UV detection and might blind
the bands in the low-wavelength range. The possibility to acquire several UV spectra
across a given LC peak allows the assessment of peak purity [131].
HPLC-DAD analysis has been applied alone for the partial characterisation of many
NPs with characteristic chromophores, mainly phenolics [132], polyketides, alkaloids, and terpenoids [131]. The technique also has been used successfully in combination with UV shift reagents,
which are classically used for the structural characterisation of flavonoids in their
pure form [119], [133]. Comparison of the genuine and shifted online DAD spectra enables a precise localisation
of the hydroxy groups on the polyphenols online. Another interesting point regarding
DAD-UV detection is that all wavelengths are stored during analysis, and thus multiple
wavelengths can be monitored at the same time for detection of different classes of
compounds. This has been found to be very useful for simultaneous detection of the
naphthodianthrones (590 nm) and phloroglucinols (270 nm) of Hypericum perforatum [18] or for the relatively selective determination of glucosinolates (227 nm), indolic
derivatives (270 nm), flavonoids and cinnamic derivatives (325 nm), and anthocyanidins
(520 nm) in different Brassicaceae [134].
As for simple HPLC-UV, applications of HPLC-DAD in the analysis of NPs are manifold
[82], [131] and cannot be extensively discussed here. HPLC-DAD systems are commonly used in
multi-hyphenated systems with MS [135] or ELSD [70] detection methods.
In [Fig. 1] (inset a), an example of a UV-DAD spectrum of a flavonoid (F) recorded online in the profiling
of the constituents of Arabidopsis thaliana is shown. The presence of two maxima at 280 and 360 nm attributed, respectively,
to the benzoic (band II) and cinnamoyl (band I) chromophore moieties was characteristic
for this type of compound. The complete dereplication was achieved thanks to the complementary
MS information obtained online (see below).
HPLC-MS, MS-MS, and MSn
HPLC-MS represents a key technique for the online identification of natural products.
Besides detection, a mass spectrometer gives the possibility of generating either
nominal mass molecular ions or accurate mass measurements for the determination of
empirical formulas [86]. Furthermore, the use of tandem or hybrid MS instruments [80] provides in-depth structural information through fragmentation of the molecular
species by CID reactions. Several reviews describe aspects related to online NP identification
for screening and dereplication [82], [114], [115], [119], [136], for quality control, for fingerprinting for authentication or standardisation [80], or for the identification of biomarkers [137].
For online dereplication purposes, the determination of molecular weight is of great
importance. This, however, necessitates the comparison of MS data obtained under different
detection conditions in order to differentiate protonated or deprotonated molecules
from adducts or fragments [119], [138]. The use of high-resolution instruments, such as a TOF-MS [34], [103] or FT-MS [139], [140] system, enables direct determination of the molecular formula of crude mixtures.
This strategic information allows for more precisely targeting the search in natural
product libraries for dereplication purposes [119].
Complementary structural information can be generated by in-source collision-induced
dissociation (CID) in HPLC-MS-MS or MSn experiments [141]. The generated CID spectra are, however, not comparable to those recorded by EI,
and this hampers a direct use of the standard EI-MS libraries for dereplication purposes.
For performing automated dereplication procedures, specific MS-MS libraries have to
be built based on standards available in a given laboratory, which consequently limits
this approach. The development of hybrid instruments combined with high-resolution
spectrometers, such as TOF, FT, or orbitrap analysers, allows the possibly to record
MS-MS spectra with high mass accuracy, facilitating the interpretation of the obtained
spectra [142].
In natural product chemistry, MS-MS spectra are mainly useful for the partial determination
of sugar sequences of various glycosides [143]; the detection of characteristic losses, such as those of prenylated compounds [144]; the classic fragmentation of flavonoids or related compounds for the determination
of substituent positions on A or B rings [145]; and the differentiation of isomers [120]. For other studies, the interpretation of the MS-MS spectra often requires the analysis
of many related products [146] in order to extract structurally relevant information and establish rules that can
be used for structure prediction. It is also worth mentioning that MS-MS is a well-established
method for the analysis of peptides and provides unambiguous information on the sequence
of amino acids based on precise fragmentation rules [147]. The method is also applicable to naturally occurring plant cyclic peptides after
conversion into acyclic forms by partial hydrolysis [148]. For the analysis of fully unknown constituents, MS-MS usually cannot provide enough
information to ascertain structure determination, and thus the combination with other
online information is mandatory.
In [Fig. 1] (inset b), an example of an MS spectrum obtained with ESI (PI) on a TOF instrument is presented
for the accurate mass determination of a flavonoid triglycoside (F) (kaempferol 3-O-β-[β-D-rhamnopyranosyl(1→2)D-glucopyranoside]-7-O-α-L-rhamnopyranoside) of Arabidopsis thaliana. As shown, the [M + H]+ ion was recorded with high precision (m/z = 741.2242) with the help of a reference compound analysed during the whole procedure
on a separated sprayer (LockSpray) [149]. This exact mass measurement enables the molecular formula determination (C33H41O19) with an accuracy of less than 5 ppm. A cross-library search with this molecular
formula and chemotaxonomic information (genus Arabidopsis) in a library of natural products (DNP Chapman and Hall [123]) enabled the dereplication of this compound. Its UV-DAD spectrum ([Fig. 1], inset a) confirmed that this compound was a flavonol derivative (see above).
HPLC-NMR (nuclear magnetic resonance)
Because of the lack of efficient commercial MS-MS databases, the dereplication process
often requires additional spectroscopic information to ascertain the identity of known
natural products or to partially identify unknown metabolites. In this respect, HPLC-NMR
provides a powerful tool that can yield important complementary information or, in
some cases, a complete structural assignment of natural products online [119], [124], [150], [151]. HPLC-NMR should ideally enable the complete structural characterisation of any
plant metabolite directly in an extract, provided that its corresponding LC peak is
clearly resolved. In practice, however, this is not entirely true, as many factors
hinder online structure determination [150]. These problems are linked mainly to the inherent low sensitivity of NMR for the
detection of microgram or sub-microgram quantities of natural products separated by
conventional HPLC and the need for solvent suppression.
Indeed, HPLC-NMR can be regarded as relatively insensitive ([Table 1]) due to the intrinsic properties of NMR detection. Consequently, the LODs are several
orders of magnitude higher than those of HPLC-UV or HPLC-MS. These limits also depend
on the type of magnet used (400 – 900 MHz) and the type of flow probe employed (standard
HPLC-NMR probes 40 – 120 μL, microcoils 20 nL-1 μL or cryo-flow probes). The mode of operation also strongly affects sensitivity. Indeed,
in the on-flow measurements the time of acquisition is limited, and only few transients
are recorded when the LC peak crosses the flow cell, while in the stop-flow mode an
important number of transients can be acquired, consequently improving the S/N ratio.
With a standard HPLC-NMR flow probe (60 μL on a 500-MHz magnet), the detection limits are about 20 μg of NP injected on-column
in the on-flow mode, but they can reach the nanogram range when HPLC-NMR is used at-line
with sensitive microflow probes [119].
HPLC-NMR, in the on-flow mode, can provide 1H-NMR spectra of the main constituent of a crude extract rapidly without the need
for complex automation. This type of information, in addition to other online spectroscopic
data (e. g., DAD and MS), may ascertain the structural determination and facilitate
the dereplication process. Examples of on-flow HPLC-NMR analyses for crude extract
profiling are manifold (e. g., for flavonoids, alkaloids, terpenes, and carotenoids)
[119], [121], [124], although a relatively limited number of NPs, essentially only the very major ones,
are detected in this way. The technique is also extremely useful for detecting compounds
that are labile or might epimerise or interconvert as a result of their isolation
[152].
One of the limiting factors of online HPLC-NMR is the need for solvent suppression,
because HPLC separation is performed with MeCN-D2O and MeOH-D2O. In practice, the very large signal of MeCN or MeOH and the residual HOD signal
are completely eliminated by powerful solvent suppression sequences. The main drawback
of this procedure is that analyte signals localised under the solvent resonances also
will be suppressed, and thus some information can potentially be lost. Another problem
occurring in HPLC-NMR is that the chemical shifts recorded in a typical reversed-phase
solvent will differ from those reported in standard deuterated NMR solvents. This
can be a drawback if precise comparisons with literature data have to be performed
[150].
In order to circumvent these problems, new approaches in this field allow use of HPLC-NMR
at-line instead of online. In this case, trapping the HPLC peaks on SPE for preconcentration
prior to NMR detection can be performed (SPE-NMR) [125], [153]. Another alternative is HPLC microfractionation of the extract, drying, and re-injection
of the concentrated HPLC peak in deuterated solvent and using microflow capillary
HPLC-NMR probes (CapNMR) [154], [155], [156]. These at-line HPLC-NMR analyses provide a good HPLC peak preconcentration and high
quality 1 D and 2 D NMR spectra in fully deuterated solvents without the need for
solvent suppression. The work at-line has the disadvantage that more sample handling
or automation is needed compared with the on-flow approach. However, these techniques
are crucial for the complete de novo structure elucidation of given HPLC peaks, as they can provide 1H-13C correlation experiments in the low microgram range [150].
Detection without HPLC separation
With the important development of multivariate data analysis techniques, the spectroscopic
methods used for HPLC detection (mainly NMR, IR, and MS) are more often being applied
to the analysis of crude extracts without prior HPLC separation for a rapid evaluation
of the composition, especially in the quality control of herbal medical products and
metabolomics [157]. For example, based on the quality control examples discussed previously for Gingko, ginseng, and Hypericum, alternative methods not requiring HPLC separation have been reported.
In the case of Ginkgo biloba, the determination of the content in allergenic ginkgolic acids has been evaluated
by direct 1H-NMR analysis of various commercial preparations without any pre-purification steps.
The aromatic protons common to all of these compounds were well separated from other
signals in the total 1H-NMR spectra of the extracts. The quantity of the compounds was calculated from the
relative ratio of the integral of these NMR peaks with an internal standard, and the
results were comparable with other chromatographic methods of quantification [158]. Similarly for Hypericum perforatum, hypericin and its derivative pseudohypericin were efficiently quantified by 1H-NMR with the specific detection of strongly de-shielded peri-hydroxyl protons of
hypericins in the region of 14 – 15 ppm in CD3OH solutions [159]. The high-throughput analysis of 80 phytopreparations of the same plant was also
efficiently performed with a near-infrared spectroscopic method. Hypericin, pseudohypericin,
and the phloroglucine derivative hyperforin were quantified simultaneously after subsequent
chemometric calculations in very short analysis times of a few seconds [160]. In the case of ginseng, metabolic fingerprinting of different preparations was
performed by 1H-NMR spectroscopy in less than 15 minutes without any pre-purification steps. Improvement
in the resolution of the 1H-NMR spectra was obtained by two-dimensional J-resolved NMR measurements. MVDA was
applied for the analysis, and PCA showed a clear discrimination among the samples.
The results demonstrate that not only ginsenosides but also alanine, arginine, choline,
fumaric acid, inositol, and sucrose differentiate the preparations from each other
[161]. For other medicinal plants, such as Galphimia glauca, popularly employed in Mexico, MVDA applied to crude extracts from different wild
plant populations provided a good mean to assess quality and enabled a linkage of
the neuropharmacological effects to given chemical profiles [162].
Thus, as shown, direct detection of given metabolites also can be performed without
HPLC separation. Such approaches are not applicable to any type of samples and require
that specific signals can be localised within the total extract spectra. However,
they represent very interesting complements to the classical HPLC profiling approaches.