Klin Monbl Augenheilkd 2014; 231(08): 788-792
DOI: 10.1055/s-0034-1368597
Kasuistik
Georg Thieme Verlag KG Stuttgart · New York

Implantation einer additiven Intraokularlinse in den Sulcus ciliaris zur Korrektur eines hochgradigen Astigmatismus nach Triple Procedure

Implantation of a Sulcus-Fixated Toric Additive Intraocular Lens in a Case of High Astigmatism after a Triple Procedure
K. Linz
International Vision Correction and Research Centre (IVCRC) & David J Apple Laboratory on Ocular Pathology, Augenklinik der Universität Heidelberg
,
G. U. Auffarth
International Vision Correction and Research Centre (IVCRC) & David J Apple Laboratory on Ocular Pathology, Augenklinik der Universität Heidelberg
,
F. T. A. Kretz
International Vision Correction and Research Centre (IVCRC) & David J Apple Laboratory on Ocular Pathology, Augenklinik der Universität Heidelberg
› Author Affiliations
Further Information

Publication History

eingereicht 31 January 2014

akzeptiert 05 May 2014

Publication Date:
15 July 2014 (online)

Zusammenfassung

Hintergrund: Residuelle Refraktionsfehler, insbesondere hochgradige Astigmatismen nach perforierender Keratoplastik, führen häufig zu einem deutlich eingeschränkten Sehvermögen. Können hohe Anisometropien nicht durch eine Brille oder Kontaktlinsen korrigiert werden, stehen verschiedene chirurgische und refraktiv-chirurgische Verfahren (Intraokularlinsenaustausch, astigmatische Keratotomie, Excimer-Laser-Behandlung, intrastromale korneale Ringsegmentimplantation und additive Intraokularlinsenimplantation) für eine visuelle Rehabilitation zur Verfügung. Torische Add-on-IOLs sind Spezialkunstlinsen, die anhand der Biometriewerte und der subjektiven Refraktion individuell für jeden Patienten angefertigt werden. Die Implantation der Linse erfolgt über einen Sklerokornealschnitt in den Sulcus ciliaris pseudophaker Augen. Je nach Hersteller können damit hochgradige Astigmatismen bis zu einer Zylinderstärke von + 30 dpt korrigiert werden.
Fallbericht: Ein 74-jähriger Mann stellte sich im Mai 2010 mit einem unkorrigierten Fernvisus von 1,0 logMAR bei dekompensierter Fuchs-Endotheldystrophie am rechten Auge in unserer Notfallsprechstunde vor. Daraufhin erfolgte im November 2010 eine Triple Procedure an diesem Auge. Postoperativ betrug der unkorrigierte Visus 0,8 logMAR, mit stenopäischer Lücke 0,5 logMAR. Aufgrund der weiterhin unzufriedenstellenden funktionellen Ergebnisse, auch nach der Fadenentfernung, mit einer Refraktion von + 5,5 dpt Sph, − 21,0 dpt Zyl bei 90° wurde die Indikation zur Add-on-Linsen-Implantation gestellt. Die individuell für den Patienten angefertigte torische Add-on-IOL wurde im Mai 2013 in den Sulcus ciliaris implantiert. Die postoperativen 8-Monats-Daten zeigten eine Astigmatismusreduktion um 96,43 %, eine Verbesserung des unkorrigierten und korrigierten Fernvisus sowie eine gut zentrierte IOL.
Schlussfolgerung: Add-on-IOL-Systeme stellen ein sicheres und effizientes Verfahren zur Korrektur hochgradiger Astigmatismen nach perforierender Keratoplastik dar. Ein entscheidender Vorteil dieses Linsenkonzepts gegenüber keratorefraktiven Verfahren besteht in der einfachen und schnellen Reversibilität durch Explantation der IOL. Des Weiteren können mit diesen speziell angefertigten torischen IOL sehr hohe Zylinder mit einer Stärke bis zu 30 dpt ausgeglichen werden.

Abstract

Background: Residual refractive errors, especially high-grade astigmatism after penetrating keratoplasty, often lead to a significant loss of vision. If high anismetropia could not be corrected with glasses or contact lenses, different kinds of surgical procedures are available for visual rehabilitation (intraocular lens exchange, astigmatic keratotomy, Excimer laser treatment, intrastromal corneal ring segment implantation and additive intraocular lens implantation). Toric add-on IOLs are especially designed for sulcus implantation and correcting high astigmatism in pseudophakic eyes. All toric IOLs are individually manufactured according to subjective refraction and biometry. Depending on the underlying manufacturer high-grade astigmatism can be corrected with a cylindrical power up to + 30.0 D.
Case Report: A 74-year-old patient presented with endothelial decompensation and an uncorrected distance visual acuity (UDVA) of 1.0 logMAR for penetrating keratoplasty on the right eye due to a Fuchs endothelial dystrophy. Postoperatively, the uncorrected distance visual acuity improved to 0.8 logMAR, with pinhole correction to 0.5 logMAR. After removing the sutures a high and irregular corneal astigmatism of 21.0 D was found. The corrected distance visual acuity (CDVA) with a refraction of + 5.5 D sph, − 21.0 D cyl 90° was 0.24 logMAR. Therefore an individually manufactured toric additive intraocular lens of + 25.0 D cylindrical and − 18.0 D spherical power for sulcus implantation was chosen and implanted uneventfully. Eight months after surgery refractive astigmatism was reduced significantly to − 0.75 D with an UDVA of 0.08 logMAR and a CDVA of 0.02 logMAR. During the 8-months follow-up period the additive IOL remained centered and no IOL rotation could be observed.
Conclusion: Toric add-on IOLs are a safe and successful method for reducing high astigmatism and anisometropia after penetrating keratoplasty. One of the main advantages is the reversibility of the procedure by an explantation of the IOL.

 
  • Literatur

  • 1 Williams KA, Ash JK, Pararajasegaram P et al. Long-term outcome after corneal transplantation. Visual result and patient perception of success. Ophthalmology 1991; 98: 651-657
  • 2 Genvert GI, Cohen EJ, Arentsen JJ et al. Fitting gas-permeable contact lenses after penetrating keratoplasty. Am J Ophthalmol 1985; 99: 511-514
  • 3 Barraquer CC, Rodriguez-Barraquer T. Five-year results of laser in-situ keratomileusis (LASIK) after penetrating keratoplasty. Cornea 2004; 23: 243-248
  • 4 Lisa C, García-Fernández M, Madrid-Costa D et al. Femtosecond laser-assisted intrastromal corneal ring segment implantation for high astigmatism correction after penetrating keratoplasty. J Cataract Refract Surg 2013; 39: 1660-1667
  • 5 Ohno K. Customized photorefractive keratectomy for the correction of regular and irregular astigmatism after penetrating keratoplasty. Cornea 2011; 30: 41-44
  • 6 Tehrani M, Schwenn O, Dick HB. Torische Intraokularlinse zur Korrektur eines höhergradigen Astigmatismus nach Keratoplastik bei Pseudophakie – eine Kasuistik. Klin Monatsbl Augenheilkd 2001; 218: 795-799
  • 7 Sauder G, Cordes A. Einsatzmöglichkeiten und Erfahrungen mit einer neuen Generation von Add-On-Linsen: die A4 W. Ophthalmo-Chirurgie 2012; 24: 1-6
  • 8 Kohnen T, Klaproth OK. Pseudophake additive Intraokularlinsen. Ophthalmologe 2010; 107: 766-772
  • 9 Sauder G. Sekundäre torische Intraokularlinsenimplantation in pseudophake Augen. Ophthalmologe 2007; 104: 1041-1045
  • 10 Thomas BC, Auffarth GU, Reiter J et al. Implantation of three-piece silicone toric additive IOLs in challenging clinical cases with high astigmatism. J Refract Surg 2013; 29: 187-193
  • 11 Rabsilber TM, Kretz FTA, Holzer MP et al. Bilateral implantation of toric multifocal additive intraocular lenses in pseudophakic eyes. J Cataract Refract Surg 2012; 38: 1495-1498
  • 12 Moustafa B, Häberle H, Wirbelauer C et al. Refraktive Langzeitergebnisse nach Huckepackimplantation. Ophthalmologe 2007; 104: 790-794
  • 13 Kook D, Bühren J, Klaproth OK et al. Astigmatische Keratotomie mit dem Femtosekundenlaser. Ophthalmologe 2011; 108: 143-150
  • 14 Poole TR, Ficker LA. Astigmatic keratotomy for post-keratoplasty astigmatism. J Cataract Refract Surg 2006; 32: 1175-1179
  • 15 Buzzonetti L, Petrocelli G, Laborante A et al. Arcuate keratotomy for high postoperative keratoplasty astigmatism performed with the intralase femtosecond laser. J Refract Surg 2009; 25: 709-714
  • 16 Hoffart L, Touzeau O, Borderie V et al. Mechanized astigmatic arcuate keratotomy with the Hanna arcitome for astigmatism after keratoplasty. J Cataract Refract Surg 2007; 33: 862-868
  • 17 Knorz MC. Derzeitiger Stand der refraktiven Chirurgie an Hornhaut und Linse. Ophthalmologe 2013; 110: 683-695